| Description | The Health & Safety is ideal for precisely determining the electrical resistance of materials and surfaces in electronics manufacturing, ESD protection, laboratories and quality control. It is used to reliably determine whether a material is conductive, static dissipative or insulating, thus making The Health & Safety is ideal for precisely determining the electrical resistance of materials and surfaces in electronics manufacturing, ESD protection, laboratories and quality control. It is used to reliably determine whether a material is conductive, static dissipative or insulating, thus making a decisive contribution to the prevention of electrostatic discharge. Thanks to its compact design and ease of use, the device is ideal for both mobile use and stationary measurements and also serves as an ESD measuring device and electrostatic measuring device. Our measuring device covers a wide measuring range from 10³ ? to 10¹? ? and offers a measuring accuracy of 1 decade. The maximum display value is 20 G?; values above this indicate that the measuring range has been exceeded. The temperature measuring range is 0 ... 50°C / 32 °F ... 122°F with a deviation of ±2°C / ±3.6°F. An automatic switch-off after approximately five minutes ensures energy-saving operation, while the integrated backlight and data hold function allow for convenient reading of the measured values.
This Health & Safety has an easy-to-read 2.2-inch LCD display showing temperature, resistance, battery status and measurement mode. Three easy-to-use buttons control all functions, such as power on/off, temperature unit switching and data hold. Power is supplied by a 9 V block battery, allowing the Health & Safety to be operated independently of the mains. The Health & Safety also allows measurements to be taken on irregularly shaped objects and provides a clear evaluation of the measurement results: Values from 10³ to 10? ? indicate conductive materials, 10? to 10¹¹ ? indicate static dissipative properties, and from 10¹² ? onwards, surfaces are considered insulating. The device thus provides a quick and precise assessment of electrostatic properties and ensures greater safety and quality in sensitive production environments.
This measuring device is ideal for specialists in electronics manufacturing, ESD officers, technicians, engineers, testing laboratories and anyone who needs to check surfaces for electrical conductivity. As an ESD measuring device and electrostatic measuring device, it also provides reliable support in complying with electrostatic protection measures.... Read More | Thanks to its wide measurement range and versatile functions, our Decibel Meter is suitable for noise measurements in industry, the environment, occupational health and safety, at events and in research. Our Decibel Meter records and visualises sound levels within a range from 20 to 130 dB in three Thanks to its wide measurement range and versatile functions, our Decibel Meter is suitable for noise measurements in industry, the environment, occupational health and safety, at events and in research. Our Decibel Meter records and visualises sound levels within a range from 20 to 130 dB in three manual measurement ranges and offers various measurement functions such as Hold, Max and Leq value. The Decibel Meter supports time weighting F, S and I as well as frequency weighting A, C and Z and can record sound within a frequency range from 25 to 130 dB.
With operation modes for Leq, 1/1 and 1/3 octave filter measurements, it covers a wide range of measurement requirements. The internal memory function enables automatic storage of up to 12 data groups for octave band measurements. In addition, up to 800 individual measurements and regular measurements can be saved over a period of up to 6 days. These functions make Decibel Meter s indispensable tools in acoustics to ensure both the protection of people and the quality of rooms and products. An RS232 interface can transfer the data via the optional software. An AC output is also available.
The Decibel Meter fulfils several standards, including IEC 61672-1, GB/T3785.2-2010 and IEC 1260-2014, all in class II, making it the ideal choice for standard-compliant measurements. The Decibel Meter is supplied with a windscreen in a practical carrying case.... Read More | Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress with their high load-bearing capacity, precise fit, and long service life – perfect for professional use in industry and assembly.... Read More | Replacement soldering tips for the PCE-ESI 100 (set of 3)
Chisel tip (flat, bevelled – for larger solder joints) Tapered tip / pointed tip (tapering to a point – for precision work) Flat tip (wider, straight-cut) | The rain and snow Temperature Sensor is used for reliable detection of precipitation and is used to monitor weather conditions in environmental stations, for irrigation control systems or in industrial plants. The rain and snow Temperature Sensor enables a quick and reliable response to rain or snowThe rain and snow Temperature Sensor is used for reliable detection of precipitation and is used to monitor weather conditions in environmental stations, for irrigation control systems or in industrial plants. The rain and snow Temperature Sensor enables a quick and reliable response to rain or snow. The Temperature Sensor qualitatively detects the presence of precipitation via conductivity and condensation properties and provides the information digitally via RS-485 Modbus RTU and via a potential-free relay output, which can be used to directly switch external devices or controls.
The integrated relay output is designed as a normally open contact and provides galvanic isolation between the Temperature Sensor voltage and the switched circuit. This allows both low-voltage and mains voltage applications to be implemented. The maximum switching capacity of the relay is 250V AC at 1 A or 30V DC at 1 A, making the Temperature Sensor suitable for direct control of controllers, actuators or relays.
The supply voltage of the rain and snow Temperature Sensor is 24 to 30V DC. The compact, corrosion-resistant housing is IP65-rated and designed for surface mounting. An automatic heating function activates at lower temperatures below 0°C / 32°F ambient temperature and heats the Temperature Sensor surface to approximately 40°C / 104°F to prevent ice formation. This ensures that the rain and snow Temperature Sensor works reliably even in frosty conditions. It is mainly used by weather station operators, environmental researchers, in irrigation systems and in industrial applications where precipitation needs to be reliably detected and automated responses implemented. ... Read More |