Like conventional microplate readers, multimode microplate readers detect reaction signals from microtiter plates in order to perform assays such as ELISA, protein detection, and drug screening assays. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. This can increase throughput and efficiency, thus saving time and space in the lab. Important things to consider when purchasing a multimode microplate reader are the particular combinations of assays desired, ease of use, ability to add or remove functionality, and the unit price.
Find, compare, and request a quote for multimode microplate readers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | Molecular Devices, LLC | Molecular Devices, LLC |
| Item | SpectraMax Mini Multi-Mode Microplate Reader | SpectraMax i3x Multi-Mode Microplate Reader |
| Citations | | |
| Figures | | |
| Catalog Number | SpectraMax Mini | i3x |
| Price | | |
| Description | The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, providing researchers with a versatile instrument that does not compromise on sensitivity or performance. Included SoftMax® Pro Software enables rapid data generation and analysis helping you achieve more in less time.
Features: - Industry-leading software - Enjoy an extensive library of protocols, advanced reader control, and easy data management and analysis with our best-in-class SoftMax Pro Software.
- Expanded wavelength range - Xenon flash lamps allow you to excite samples in the UV range where halogen does not.
- Approachable design - Effortless functionality provides users with everything they need to run their most crucial applications quickly and without complications.
- AutoPMT technology - Our AutoPMT feature allows a wide range of concentrations to be prepared and read on one plate, avoiding saturation (or the loss of signal) and saving you time and money.
... Read More | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications - User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis - The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality - Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis - Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include: - Capture flash assays with ease
- Reduce background noise
- Increase fluorescence performance
... Read More |
| Reading Modes | UV-Vis absorbance, Fluorescence, and Luminescence | Absorbance, Fluorescence (top/bottom read), Luminescence (top read), Time-Resolved Fluorescence (top read), Fluorescence Polarization (top read), HTRF (top read), AlphaScreen (top read) |
| Optical System | Two high-energy xenon flash lamps | Spectral Fusion Illumination |
| Wavelength Range | 200 to 1000 nm | 230 to 1000 nm |
| Plate Formats | 6, 12, 24, 48, 96, 384-well plates ANSI/SLAS | 6 to 1536 wells |
| Temperature Control | Inquire | 4°C above ambient to 45°C |
| Get Quote | | |