Description | Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling allows for perfectly timed, automated biochemical and cell-based assays. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics.
Onboard pipettor -
Integrated 8-channel or 16-channel pipettor increases assay flexibility by transferring reagents from 96 or 384 distinct wells in a source plate to the read plate.
Optimal assay excitation -
Dual monochromators allow users to target the optimal assay excitation and emission wavelengths and eliminate the need to change expensive band pass filters between experiments.
Low volume applications -
SpectraDrop™ Micro-Volume Microplate offers a high-throughput solution for low volume measurement, accelerating sample preparation time and increased productivity in DNA, RNA and protein research.
Robot integration -
The FlexStation 3 reader can be integrated with all leading partner robots and with our out-of-the-box automation solution for savings on up-front integration time and resources.
Other features and benefits include: -
- Enable more assay conditions
-
Automate pipetting
-
Validate your reader
... Read More | Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for Affordability and unmatched assay performance in filter-based microplate readers.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. They provide absorbance, fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements.
Visible absorbance -
This reader provides visible absorbance, top-reading fluorescence intensity, and glow luminescence modes in 96- to 384-well plates with wavelength selection options from 340-650 nm.
UV and visible absorbance -
This reader provides UV and visible absorbance, top and bottom fluorescence intensity, glow luminescence, FP, and TRF modes in 6- to 1536-well plates with wavelength selection options from 230-750 nm.
Other features and benefits include:
- Get great performance with LEDs
-
Count single photons
-
Get tailored data analysis
... Read More | The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. As new assays are developed or your needs change, simply add a cartridge or the SpectraMax® MiniMax™ Imaging Cytometer option as opposed to buying a brand new system.
Features - User-Upgradeability Expand the 3-mode base system with additional application cartridges for FP, HTRF®, AlphaScreen® assays, and cellular imaging
- SpectraMax® MiniMaxTM Imaging Cytometer simplifies complex imaging workflow by visualizing cell morphology changes on top of well-based intensity readings
- Spectral FusionTM Illumination delivers a high-powered, full spectrum light source for increased fluorescence performance across the entire excitation range
- Expanded Dynamic Range: sophisticated engineering delivers optimal sensitivity and maximizes signal range
- SoftMax® Pro Microplate Data Acquisition & Analysis Software: Industry-leading SoftMax Pro Software streamlines complex data analysis with over 140 built-in protocols, effectively eliminating the need for additional software. Additional tools for regulatory compliance are included in SoftMax Pro GxP Software
... Read More | NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET,NFC-based personalization and enhanced touchscreen workflows provide walk-up usability
The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection.
With optimized reagents, option to operate the readers using the touchscreen or a computer, and industry-leading SoftMax® Pro Software, the readers provide an all access pass for breakthrough research.
QuickSync - The QuickSync feature pushes data to any computer within the same network and delivers data in an Excel-compatible format.
Flexible temperature control - Simple-to-use temperature control adjusts the experiment's conditions from ambient up to 66°C.
Automatic filter identification - Using NFC tags, the SpectraMax iD5 reader automatically detects the wavelength properties of each filter in addition to the filter slide configuration, eliminating confusion and the need for manual information entry.
Enhanced security - The SoftMax® Touch Software secures user accounts with PIN- or NFC-protection with a lock screen option. Data is stored on the reader’s hard drive ensuring security even after transfer to a computer.
Hybrid optical system - The SpectraMax iD5 reader provides the flexibility to set up experiments using filters, or a monochromator in 1 nm increments, or a hybrid mix of monochromator and filter-based wavelength selection.
Flash assays captured with ease - The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 µL), overflow protection, and ensures equal mixing across the plate for high-precision experiments.
Other features and benefits include: - Personalize workflows
- • Simplify tasks
- • Reduce background noise
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More |
Reading Modes | Absorbance Photometric, Fluorescence Intensity, Fluorescence Polarization, Time-resolved Fluorescence, Luminescence | Endpoint, Kinetic, Linear Scan, Area Scan | Endpoint reading, Kinetic reading | iD3 - Absorbance, Fluorescence, Luminescence
iD5 - Absorbance, Fluorescence, Luminescence, Time-Resolved, Fluorescence, Fluorescence Polarization, HTRF, HTRF | Absorbance, Fluorescence, Luminescence,Time-Resolved Fluorescence, Fluorescence Polarization, HTRF |