Description | Sets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggeringSets the enduring standard for microplate analysis using filters for end-point absorbance measurements.
The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. A staggering mean time between failure (MTBF) of 20,000 hours is achieved by 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts. No optical alignment needed during the lifetime of the instrument!
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay, the EMax Microplate Reader has both the speed and performance to carry a heavy workload.
The EMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
EMax Microplate Readers can be operated as a stand-alone instrument and is also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Solid Performance for Dedicated Absorbance
- Enabling Features
- Read up to 2 wavelengths in endpoint absorbance for 96-well plates.
- Mix samples in microplate wells by user-programmable Automix feature.
- Operate without an attached computer using the onboard microprocessor.
- Add assay flexibility with additional filters.
- Comprehensive Reader Validation
... Read More | Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are a high-throughput automated solutions for imaging and analyzing mammalian cells. Tracking the formation of a colony from a single cell is effortless as barcoded plates are tracked over time. Automated acquisition and analysis provides accurate, objective, and consistent results.
With high-resolution white light imaging, the CloneSelect Imager provides automated confluence, monoclonality assurance and industry leading acquisition times with the ability to image a 96-well plate in under two minutes.
The CloneSelect Imager FL features high contrast multichannel fluorescent and white light imaging that allows for accurate single cell detection and proof of monoclonality at day 0. Streamline your workflow with comparative confluence assays to identify and verify gene edits.
Features :
- White light and fluorescent imaging -
Image every well in every plate with rapid acquisition times with label-free white light. Multichannel fluorescence imaging provides additional confidence of monoclonality and comparative confluence assays (red vs green). -
Data tools to accelerate research timelines -
The software automatically calculates confluence measurements and generates growth curves, heatmaps, and image montages. Measurements for every well are automatically tracked over time. Streamline multiple steps (imaging, sample tracking, data analysis and report generation) in the cell line development workflow for IND filing. -
Quickly image a variety of plate formats and cell types -
Image a 96-well plate in under two minutes. Compatible with adherent or settled suspension cell types such as CHO, HEK, hybridomas, iPSCs, and many other cell types. -
Intelligent analysis with easy-to-use software -
The software automatically calculates confluence for each imaging time point. Growth curve, image montage, total growth, and mean rate are generated automatically and are exportable. Guided software user interface allows for simple 1-hour training. -
High-resolution images -
High-speed fluorescence and high-resolution white light imaging with accurate detection of single cells including debris. Image visualization and data tracking over multiple days. -
Custom automation options -
The Automation and Customization Team offers a variety of custom services from robotic plate loading to fully automated workstations with liquid handling and incubation. We have built out custom automated work cells with the CloneSelect Imager for iPSC workflows, full assay systems and drug toxicity and characterization research. ... Read More | Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both Filterless readers provide consistent results with steady temperature regulation.
The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Both readers feature an 8-channel read head for fast reads and a subset feature our patented PathCheck™ Sensor. The temperature independent PathCheck sensor automatically normalizes and ensures accurate absorbance values by detecting pipetting errors. Combined with a wide application base, industry-leading SoftMax® Pro Software and validation tools, these readers fit in every lab and every budget.
Pipetting errors eliminated - This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. It also allows for the elimination of standard curves.
Optimized optical path - The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. The spectral resolution ensures accuracy of DNA absorbance measurements.
Eight-channel optics - The optical design of the reader mimics a dual-beam spectrophotometer. Each well has its own sample beam and reference detector. The eight-channel system delivers both precision and speed across the microplate.
Dual wavelength reads - The reader delivers high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength making data analysis convenient.
Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate.
Validation made easy - Verify the accuracy of your absorbance measurements with the SpectraTest® ABS1 Absorbance Validation Plate, using NIST-traceable standards. Testing can be done in your own lab, on your own schedule.
Other features and benefits include: - Eliminate filters
- Get consistent results
- Integrate with ease
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment -
The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes -
Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity -
Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include:
- Get automatic Z-height optimization
-
Eliminate manual gain adjustment
-
Tailor your data analysis
... Read More |