Description | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications -
User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis -
The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality -
Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis -
Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include:
- Capture flash assays with ease
-
Reduce background noise
-
Increase fluorescence performance
... Read More | Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay Multi-wavelength measurement without filters.
The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay sensitivity. Comparison of relative fluorescence units (RFUs) between samples is allowed by a unique calibration against an internal standard. Temperature-sensitive reactions are monitored with consistent temperature regulation from ambient to 45°C.
Top-read capability -
The top-reading Gemini XPS Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Top- and bottom-read capability -
The top- and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Other features and benefits include:
- Eliminate changing out filters
-
Measure more accurately
-
Avoid losing high signal
... Read More | Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for Enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility.
Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). Narrow bandwidths deliver increased accuracy and enhanced peak resolution. Never order or replace filters to optimize an assay again!
A patented multichannel optical design mimics a dual-beam spectrophotometer, measures each sample in the plate directly, and eliminates error due to variations in light output between optical fibers on other instruments for more reliable reporting. The eight-channel system delivers high precision and speed when reading 96-well microplates for single endpoint measurements and kinetic assay data gathered over time.
The VersaMax Microplate Reader is supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. Additionally, the VersaMax Microplate Reader can be seamlessly integrated with the StakMax® Microlate Handling Stacker through the SoftMax Pro Software.
Features - Enabling Assays without Compromise
- Measuring Accurately and Reproducibly
- Comprehensive Reader Validation
- Automating with Ease
... Read More | The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between The VMax® Kinetic ELISA Microplate Reader, the first of its kind for monitoring reactions over time, opened the door to enzyme assays and continues to be the workhorse of the laboratory environment. Based on a rugged, simple design, the VMax Absorbance Microplate Reader offers a mean time between failure (MTBF) of 20,000 hours with 97 independent and stationary fiber optics so that the microplate remains stationary during the entire reading cycle, reducing the number of moving parts that can wear and need replacement.
Through sequential, single-well illumination, 100% of the available light is directed to each well through the optical fibers to achieve linearity to higher optical densities (ODs) and optimal signal-to-noise ratios. At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance.
The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices.
VMax Microplate Readers can be operated as stand-alone instruments and are also supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software.
Features - Extend uptime with an estimated 20,000 hour mean time between failure
- Maximize assay signal-to-noise ratios through a unique optical system that directs all available light to each well
- Achieve higher throughput with a 5 second microplate read time
- Read up to 2 wavelengths in endpoint or kinetic absorbance for 96-well plates
- Mix samples in microplate wells by user-programmable Automix feature
- Operate without an attached computer using the onboard microprocessor
- Add assay flexibility with additional filters
... Read More |