The fume hood is an important piece of laboratory safety equipment designed to protect personnel and the environment from toxic fumes by drawing air from a contained area. The lining material of a fume hood confers its containment properties and polypropylene offers many advantages in this regard. Some of these include its impermeability, durability, and resistance to corrosion. For this reason, polypropylene fume hoods are recommended for most applications. When purchasing a polypropylene fume hood, some factors to consider include the size of the hood—most common sizes run from 3-8 feet, whether your lab has ducting capabilities or if a ductless model is needed, whether a constant volume or variable air volume exhaust system will be used, the material and operating speed of the blower, sash height, and the benchtop material. After purchase, fume hoods require regular maintenance and adherence to safety guidelines; always be sure to follow manufacturer instructions to ensure maximum safety.
|  |  |  |  |  |
| Company | AirClean Systems | AirClean Systems | AirClean Systems | AirClean Systems | AirClean Systems |
| Item | AirMax® Fume Hood with Wet Fume Scrubber | Endeavour™ Ductless Fume Hood - Folding Sash | Endeavour™ Ductless Fume Hood - Sliding Sash | Free-Standing Clean Room Enclosures | Polypropylene Free-Standing Recirculating Fume Hoods |
| Catalog Number | AC3030TE / AC4030TE / AC5030TE / AC6030TE / AC8030TE | ACPT3000 / ACPT3036 / ACPT4000 / ACPT4036 / ACPT5000 / ACPT5036 / ACPT6000 / ACPT6036 | ACPT3000S / ACPT3036S / ACPT4000S / ACPT4036S / ACPT6000S / ACPT6036S / ACPT8000S / ACPT8036S | AC6000DF / AC8000DF | AC3000E / AC4000E / AC6000E |
| Price | | | | | |
| Size(s) | 36, 48, 60, 72 and 96 in. | 36, 48, 60 and 72 in | 36, 48, 72 and 96 in | 6 and 8 ft. | 36, 48 and 72 in |
| Type | Polypropylene/ Polycarbonate | Polypropylene | Polypropylene | Polypropylene | Polypropylene |
| Exterior Dimensions | varies with model | varies with model | varies with model | varies with model | varies with model |
| Interior Dimensions | varies with model | varies with model | varies with model | varies with model | varies with model |
| Depth | Inquire | Inquire | Inquire | Inquire | Inquire |
| Description | AirMax, with wet fume scrubber, is a total solution for minimizing personnel, ductwork and environmental exposure to caustic acid gases. Contaminated air passes through the scrubber’s water-washed contact media before being exhausted. The water used during the scrubbing process is captured in the AirMax, with wet fume scrubber, is a total solution for minimizing personnel, ductwork and environmental exposure to caustic acid gases. Contaminated air passes through the scrubber’s water-washed contact media before being exhausted. The water used during the scrubbing process is captured in the holding tank and recirculated. An optional pH dosing system can be added to neutralize acids captured during the scrubbing process.... Read More | Endeavour™ ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure. Endeavour™ gives you the versatility and flexibility expected from modern laboratory equipment
Features - Touch screen automatic safety controller
- Large capacity filtration bed for
Endeavour™ ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure. Endeavour™ gives you the versatility and flexibility expected from modern laboratory equipment
Features - Touch screen automatic safety controller
- Large capacity filtration bed for variety of application challenges
- Integral polypropylene spill tray
- Advanced airflow monitoring and controller
- Single wall structure polypropylene design to maximize work area
- AirZone baffling to promote uniform airflow and contaminate containment
- Folding polycarbonate sash that allow free range of monitor for application manipulation
... Read More | Endeavour™ ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure. Endeavour™ gives you the versatility and flexibility expected from modern laboratory equipment
Features - Touch screen automatic safety controller
- Large capacity filtration bed for
Endeavour™ ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure. Endeavour™ gives you the versatility and flexibility expected from modern laboratory equipment
Features - Touch screen automatic safety controller
- Large capacity filtration bed for variety of application challenges
- Integral polypropylene spill tray
- Advanced airflow monitoring and controller
- Dual wall design to allow for placement of fixtures, taps and electrical outlets like a typical total exhaust fume hood
- Vertical sliding safety glass sash
... Read More | AirClean® Systems free-standing, polypropylene vertical laminar flow clean room hoods protect the application from airborne particulate contamination. Designed to bathe the process in HEPA clean air, a polypropylene free-standing hood is ideal for enclosing pipettors, equipment that requires a AirClean® Systems free-standing, polypropylene vertical laminar flow clean room hoods protect the application from airborne particulate contamination. Designed to bathe the process in HEPA clean air, a polypropylene free-standing hood is ideal for enclosing pipettors, equipment that requires a particle-free environment or creating clean rooms within a large manufacturing facility or warehouse for product sampling.
Free-standing enclosures provide a variety of options for clean rooms, from small drum sampling stations to enclosing complete assembly applications. Contact one of our qualified technical sales specialists to determine which clean room hood best fits your needs.
Features - UVTect™ microprocessor controller
- Solid polypropylene construction for maintaining a clean environment
- Fluorescent light
- Easy access for filter change
- Standard with HEPA filter but may be fitted with ULPA filters
... Read More | AirClean® Systems polypropylene free-standing recirculating fume hoods are designed to accommodate applications that require additional vertical height not found in standard benchtop hoods. Typically floor mounted, each E-Series recirculating fume hood features an upper folding sash combined AirClean® Systems polypropylene free-standing recirculating fume hoods are designed to accommodate applications that require additional vertical height not found in standard benchtop hoods. Typically floor mounted, each E-Series recirculating fume hood features an upper folding sash combined with lower access doors, providing easy ergonomic access during manipulation. Full access design allows equipment to be easily inserted or removed from the enclosure, making the E-Series perfect for use with mixers, mills, grinders, reactors, or other tall equipment.
Features - AirSafe™ automatic safety controller
- Wide range of activated bonded carbon, impregnated chemisorptive, and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
- Polypropylene construction for excellent chemical resistance
- Full access for equipment loading and application viewing
- Integral vapor-proof fluorescent lighting
- No installation costs. All AirClean® Systems hoods are shipped fully assembled (filters installed) and ready to use
- No ducting required
- Available in 110V or 220V AC versions
... Read More |
| Quantity | EA | EA | EA | EA | EA |
| Get Quote | | | | | |