A chemical fume hood protects lab workers by venting solvent fumes and other harmful gases out of the laboratory and the indoor room air. Air flows into the cabinet beneath a movable sash at the front, and carries fumes up and out through the vent. Bypass fume hoods have an additional air intake above the sash which minimizes disruption of air flow in the work area due to movements in and out of the hood. Options in chemical fume cabinets now include energy efficient low flow fume hoods and hoods with an outdoor air intake (also known as auxiliary fume hoods) to avoid venting conditioned room air. Chemical fume hoods designed for specialized uses such as working with radioisotopes or perchloric acid are also available.
Click here for
Ductless Fume Hoods
|  |  |  |  |
| Company | TopAir Sytems Inc. | TopAir Sytems Inc. | TopAir Sytems Inc. | TopAir Sytems Inc. |
| Item | Polypropylene Fume Hood – Washdown | Ductless Fume Hood- Pro EN-14175 / ASHRAE 110 | Opioid Evidence Handling Workstation Kit | Value Line Ductless Fume Hood |
| Catalog Number | FH-120-WD / FH-150-WD / FH-180-WD / FH-200-WD / FH-250-WD | CF-060-PP / CF-090-PP / CF-120-PP / CF-150-PP / CF-180-PP | CF-060-OP / CF-090-OP / CF-120-OP / CF-150-OP / CF-180-OP | VL-CF-090-PP / VL-CF-120-PP / VL-CF-150-PP / VL-CF-180-PP |
| Price | | | | |
| Size(s) | Varies with model | 23.62, 35.4, 47.24, 59, and 70.8 in | Inquire | 35.4, 47.2, 59, and 70.8 in |
| Type | Fume Cupboard | Ductless Fume Hood | Inquire | Ductless Fume Hood |
| Exterior Dimensions | (WxDxH) 1200 x 980 x 2370 mm to 2500 x 980 x 2370 mm (47.3 x 38.6 x 93.3 in. to 98.4 x 38.6 x 93.3 in.) | (WxDxH) 600 x 750 x 1223 mm23.62 x 29.5 x 48” to 1800 x 750 x 1223 mm 70.8 x 29.5 x 48” | Varies with model | (WxDxH) 900 x 630 x 1050 mm 35.4 x 24.8 x 41.3? to 1800 x 630 x 1050 mm 70.86 x 24.8 x 41.3? |
| Depth | 24.8 in. | Inquire | Inquire | Inquire |
| Description | TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance. The fume hoods protect laboratory staff from noxious fumes released by acids, dangerous gas and organic solvents — materials and acids that regular steel hoods may not withstand. The hoods are designed for work with heavy chemicals and have been independently tested and CE certified.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – optional materials include stainless steel, ceramic, epoxy, and HPL.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation from both the top and rear panel
Features: - Washdown functionality
- Spray nozzles
- Solenoid tap for washdown
- Draining port
- Easy access for maintenance and repairs
- 7” color touch screen controlling lighting and power outlets
- Optional upgrade to control systems:
- 7“screen with AFA system – Air velocity display and Alarm
- 10.1” VAV – Automatic air velocity control (installed and include VFD), temp & humidity display
- Energy saver 10.1” VAV+Active, with automatic sash motion and proximity sensing system that dramatically reduces energy costs
- 800 lux LED lighting separated from the work area (option for explosion proof light)
- CE certified
... Read More | TopAir’s polypropylene Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
Our Ductless Fume Hood offers an air velocity display and alarm with a full Variable Air Volume (VAV) automatic speed adjustment to meet 100±20 fpm (0.5±0.1 m/s). This model is TopAir’s polypropylene Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
Our Ductless Fume Hood offers an air velocity display and alarm with a full Variable Air Volume (VAV) automatic speed adjustment to meet 100±20 fpm (0.5±0.1 m/s). This model is also equipped with a chemical VOC sensor and alarm to detect high levels of volatile compounds present in the filter for extra safety.
TopAir’s Ductless Fume Hoods can be customized to meet size requirements as needed.
Structure:- 8 mm welded polypropylene with high chemical resistance
- Built-in sealed polypropylene worktop or choice of epoxy, stainless steel, ceramic, or Trespa high pressure compact laminates (HPLs)
- 5 mm safety front glass window with sliding front sash with counterweight
- Side windows for better visibility
Features:- 10.1” color touchscreen display
- VAV with air flow alarm and display
- VOC sensor and alarm
- Chamber alert light (red) for critical alarms
- High efficiency quiet ECM fan
- 800 lux LED lighting separated from the work area
- Adjustable air velocity 100±20 fpm (0.5 ± 0.1 m/s)
- Convenient front access for filter replacement
- Variety of HEPA filters, carbon filters, and pre-filters
- 10” (250 mm) exhaust point collar for connection to external exhaust
- Optional: metal stand or polypropylene base cabinet
- Certifications: EN-14175 / ASHRAE 110-1995, CE
... Read More | TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places. TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places.
- Dual ULPA filter The ULPA filter includes a main filter and a secondary back up filter. It removes powders and particles with an efficiency of 99.9995 @ 0.3µm and provides reassurance to the to the lab staff.
- Vacuum system for efficient residue collection The vacuum system is an excellent instrument to collect residues of powders from the working surface and channel them to the ULPA filter.
- Filter integrity test after production (D.O.P) This test provides reassurance to lab staff about air quality and contamination control in the laboratory environment
... Read More | TopAir’s Valueline Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
This cost-effective benchtop ductless fume hood with an innovative, intelligent control system includes a 7” color touchscreen with airflow monitoring, alarm, integral polypropylene TopAir’s Valueline Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
This cost-effective benchtop ductless fume hood with an innovative, intelligent control system includes a 7” color touchscreen with airflow monitoring, alarm, integral polypropylene worktop, a sliding front sash with counterweight, an environmentally friendly EC fan, and LED light.
A variety of filters can be supplied for maximum protection from most common chemical fumes.
TopAir’s Value-line Ductless Fume Hoods can be customized meet size requirements as needed.
Structure:- 8 mm welded Polypropylene with high chemical resistance
- Built-in sealed polypropylene worktop
- 5 mm safety front glass window with sliding front sash with counterweight
- Side windows for better visibility
Features- 7” color touchscreen display
- Airflow display and alarm
- 10 speed fan control
- Chamber alert light (red) for critical alarms
- Built-in sealed polypropylene worktop
- Tempered glass side windows and sliding front sash with counterweight
- 800 lux LED lighting
- Air velocity 100±20 fpm (0.5±0.1 m/s)
- Back access for filter replacement
- Variety of HEPA and carbon filters
- EC fan with 10 levels of speed adjustment
- 10” (250 mm) exhaust collar for connecting to external exhaust
- Optional: metal stand or polypropylene base cabinet
- Certification: CE
... Read More |
| Quantity | EA | EA | EA | EA |
| Get Quote | | | | |