| Catalog Number | FH-120-WS / FH-150-WS / FH-180-WS / FH-200-WS / FH-250-WS | ECO-CF-075 / ECO-CF-090 / ECO-CF-120 | FH-090/FH-120 / FH-150 / FH-180/FH-200 AND ANY SIZE PER REQIRE | CF-060-OP / CF-090-OP / CF-120-OP / CF-150-OP / CF-180-OP | FH-120-WD / FH-150-WD / FH-180-WD / FH-200-WD / FH-250-WD |
| Description | TopAir’s Polypropylene Fume Hood – Wet Scrubber features a quality scrubbing media which collects mist and chemicals and channels these down to the water tank. Its upper eliminator prevents mist from reaching the exhaust fan. The fume hood is used to filter out acids and prevent them from being TopAir’s Polypropylene Fume Hood – Wet Scrubber features a quality scrubbing media which collects mist and chemicals and channels these down to the water tank. Its upper eliminator prevents mist from reaching the exhaust fan. The fume hood is used to filter out acids and prevent them from being released into the environment. The scrubber is built-in as an integrated part of the hood. The polypropylene fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance.
The fume hoods protect laboratory staff from noxious fumes released by acids, dangerous gases and organic solvents. The hoods are designed for work with heavy chemicals and have been independently CE certified.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – optional materials include stainless steel, ceramic, epoxy and HPL.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation from both the top and rear panel
Features: Wet scrubber functionality comprises: - Spray Nozzles
- Upper mist Eliminator
- Scrubbing Media
- Water Pump
- Water Tank
- Easy access for maintenance and repairs
- 800 LUX LED lighting separated from the work area (option for ex-proof light)
- 7” color touch screen controlling lighting and power outlets
- Optional upgrade to control systems:
- AFA system includes 7“screen with air velocity display and alarm
- VAV system includes 10.1” screen with automatic air velocity control (installed and include VFD), temp & humidity display
- Active system includes 10.1” with automatic sash motion and proximity sensing system dramatically reducing energy costs
- Optional accessories such as taps, sinks, sockets, scaffolding, and outdoor fan
- Option for PH meter with an automatic dosing pump system
- CE certified
... Read More | TopAir’s Ecoline Ductless Fume Hood provides a safe environment for lab staff working with acids and harsh chemicals.
This is the most cost-effective model of TopAir’s duct-less fume hoods product line, with an analog on/off control system, speed adjustable EC fan, and LED light.
Suitable for simple TopAir’s Ecoline Ductless Fume Hood provides a safe environment for lab staff working with acids and harsh chemicals.
This is the most cost-effective model of TopAir’s duct-less fume hoods product line, with an analog on/off control system, speed adjustable EC fan, and LED light.
Suitable for simple applications, educational uses, and small labs, it is a lightweight benchtop cabinet (metal stand is optional) with a small footprint.
Structure:- 8 mm welded Polypropylene structure with high chemical resistance
- Built-in sealed polypropylene
- Tempered glass partial sliding front sash with a max working height of 8” (200 mm)
- Analog control on/off system
Features Manual Analog on/off system with fan speed adjuster- 600 lux LED lightun
- Adjustable air velocity: 100±20 fpm (0.5±0.1 m/s
- Variety of HEPA and carbon filters
- ECM fan
- CE certified, complies with AFNOR NF X 15-211:2009 standard
... Read More | TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-1995 certified.
Structure: - Metal epoxy-coated paint
- The internal lining is made of 5 mm HPL
- Ceramic worktop is included – optional materials include stainless steel, polypropylene, epoxy, and HPL
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of epoxy-painted metal
- Air ventilation from both the top and rear panels
FEATURES - Basic control system is a 7” color touch screen controlling lighting and power outlets
- Optional upgrades to control systems:
- AFA system – includes a 7” screen with air velocity display and alarm
- VAV system includes a 10.1” screen with automatic air velocity control (installed and included VFD), temp & humidity display
- Active system has a 10.1” screen with an energy saver that includes automatic sash motion with the proximity sensing system
*An active system dramatically reduces energy costs - 800 lux LED lighting separated from the work area (option for explosion-proof light)
- Optional accessories such as taps, sinks, sockets, scaffolding, and an outdoor fan
- EN-14175, ASHRAE 110-1995, CE certified
... Read More | TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places. TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places.
- Dual ULPA filter The ULPA filter includes a main filter and a secondary back up filter. It removes powders and particles with an efficiency of 99.9995 @ 0.3µm and provides reassurance to the to the lab staff.
- Vacuum system for efficient residue collection The vacuum system is an excellent instrument to collect residues of powders from the working surface and channel them to the ULPA filter.
- Filter integrity test after production (D.O.P) This test provides reassurance to lab staff about air quality and contamination control in the laboratory environment
... Read More | TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance. The fume hoods protect laboratory staff from noxious fumes released by acids, dangerous gas and organic solvents — materials and acids that regular steel hoods may not withstand. The hoods are designed for work with heavy chemicals and have been independently tested and CE certified.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – optional materials include stainless steel, ceramic, epoxy, and HPL.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation from both the top and rear panel
Features: - Washdown functionality
- Spray nozzles
- Solenoid tap for washdown
- Draining port
- Easy access for maintenance and repairs
- 7” color touch screen controlling lighting and power outlets
- Optional upgrade to control systems:
- 7“screen with AFA system – Air velocity display and Alarm
- 10.1” VAV – Automatic air velocity control (installed and include VFD), temp & humidity display
- Energy saver 10.1” VAV+Active, with automatic sash motion and proximity sensing system that dramatically reduces energy costs
- 800 lux LED lighting separated from the work area (option for explosion proof light)
- CE certified
... Read More |