| Catalog Number | FH-090 / FH-120 / FH-150 / FH-180 / FH-220 AND ANY SIZE PER REQIRE | FH-120-WI-PP-H / FH-150-WI-PP-H / FH-180-WI-PP-H / FH-200-WI-PP-H / FH-250-WI-PP-H | CF-060-OP / CF-090-OP / CF-120-OP / CF-150-OP / CF-180-OP | FH-120-WD / FH-150-WD / FH-180-WD / FH-200-WD / FH-250-WD | CF-060-PP-W / CF-090-PP-W / CF-120-PP-W / CF-150-PP-W / CF-180-PP-W |
| Description | TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when
working with dangerous gases, organic solvents, etc.
The fume hood channels chemical vapors out of the building using an outdoor fan
installed on the roof or on an external wall.
The hoods are EN-14175 / CE / ASHRAE
110-1995 TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when
working with dangerous gases, organic solvents, etc.
The fume hood channels chemical vapors out of the building using an outdoor fan
installed on the roof or on an external wall.
The hoods are EN-14175 / CE / ASHRAE
110-1995 certified.
Structure:
Metal epoxy-coated paint
The internal lining is made of 5 mm HPL
Ceramic worktop is included – optional materials include stainless steel,
polypropylene, epoxy, HPL.
5 mm front safety glass window with counterweight system
Lower vented base cabinet made out of epoxy painted metal
Air ventilation from both the top and rear panel... Read More | TopAir’s Floor-Mounted Fume Hood offers a large front opening designed to contain bulky, heavy, or tall equipment. The fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance. The Polypropylene Fume Hoods protect laboratory staff from noxious fumes releasedTopAir’s Floor-Mounted Fume Hood offers a large front opening designed to contain bulky, heavy, or tall equipment. The fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance. The Polypropylene Fume Hoods protect laboratory staff from noxious fumes released by acids, bases, dangerous gases and organic solutions that regular steel hoods may not withstand. The fume hood channels chemical vapors out of the building using an external fan installed on the roof or on an external wall. The hoods are designed for work with heavy chemicals and have been independently CE certified.
Structure: - 8 mm welded polypropylene with high chemical resistance
- 5 mm front safety glass window with counterweight system
- Air ventilation from both the top and rear panel
- horizontal sliding sash
Features: - Basic control system: a 7” color touch screen controlling lighting and power outlets
- Optional upgrade to control systems:
- AFA: 7” screen with AFA system air velocity display and alarm
- VAV: 10.1” screen with VAV system automatic air velocity control (installed and include VFD), temp & humidity display
- 800 lux LED lighting separated from the work area (option for explosion-proof light)
- Optional accessories such as taps, sinks, sockets, scaffolding, outdoor fan
- CE certified
... Read More | TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places. TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places.
- Dual ULPA filter The ULPA filter includes a main filter and a secondary back up filter. It removes powders and particles with an efficiency of 99.9995 @ 0.3µm and provides reassurance to the to the lab staff.
- Vacuum system for efficient residue collection The vacuum system is an excellent instrument to collect residues of powders from the working surface and channel them to the ULPA filter.
- Filter integrity test after production (D.O.P) This test provides reassurance to lab staff about air quality and contamination control in the laboratory environment
... Read More | TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene TopAir’s Polypropylene Fume Hood – Washdown includes water sprinklers that allow complete and effective rinsing of the hood’s back space while collecting residue of mineral accumulation. The hood is designed for work with perchloric acid; rinses after each session is recommended. The polypropylene fume hoods are made of high-quality non-corrosive polypropylene with excellent chemical resistance. The fume hoods protect laboratory staff from noxious fumes released by acids, dangerous gas and organic solvents — materials and acids that regular steel hoods may not withstand. The hoods are designed for work with heavy chemicals and have been independently tested and CE certified.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – optional materials include stainless steel, ceramic, epoxy, and HPL.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation from both the top and rear panel
Features: - Washdown functionality
- Spray nozzles
- Solenoid tap for washdown
- Draining port
- Easy access for maintenance and repairs
- 7” color touch screen controlling lighting and power outlets
- Optional upgrade to control systems:
- 7“screen with AFA system – Air velocity display and Alarm
- 10.1” VAV – Automatic air velocity control (installed and include VFD), temp & humidity display
- Energy saver 10.1” VAV+Active, with automatic sash motion and proximity sensing system that dramatically reduces energy costs
- 800 lux LED lighting separated from the work area (option for explosion proof light)
- CE certified
... Read More | Topair’s Weighing Station is designed for weighing powders and chemicals, and provides precise weighing data with up to 4 decimal places.
It also provides a safe work environment for lab staff working with acids and harsh chemicals.
The electrical and mechanical components are manufactured by leading Topair’s Weighing Station is designed for weighing powders and chemicals, and provides precise weighing data with up to 4 decimal places.
It also provides a safe work environment for lab staff working with acids and harsh chemicals.
The electrical and mechanical components are manufactured by leading global companies, such as AAF USA. The products are EN-14175 / CE / ASHRAE 110-1995 certified.
Advanced Operation System- Color 5" touch screen
- 10-speed fan
- Hour counter for filter
- Filter replacement alarm
TopAir’s weighing stations can be customized to the requirements of each client.
Features:Provides precise weighing data – up to 4 decimal placesPolypropylene structure with high chemical resistance7” control touch screen controlling lighting and powerBuilt-in sealed polypropylene worktop or choice of epoxy, stainless steel, ceramic, TrespaTempered glass sliding front windowHigh efficiency, quiet EC fanEco-friendly, cost-effective 800 LUX LED lighting separated from the work areaWind speed at 0.5±0.1 m/s, 100±20 FPMHEPA filter installedConvenient front access for filter replacementAir flow alarmOptional: No worktop, with independent table or optical table, standXL model with 2 internal filters is also availableEN-14175 / CE / ASHRAE 110-1995 certified... Read More |