A chemical fume hood protects lab workers by venting solvent fumes and other harmful gases out of the laboratory and the indoor room air. Air flows into the cabinet beneath a movable sash at the front, and carries fumes up and out through the vent. Bypass fume hoods have an additional air intake above the sash which minimizes disruption of air flow in the work area due to movements in and out of the hood. Options in chemical fume cabinets now include energy efficient low flow fume hoods and hoods with an outdoor air intake (also known as auxiliary fume hoods) to avoid venting conditioned room air. Chemical fume hoods designed for specialized uses such as working with radioisotopes or perchloric acid are also available.
Click here for
Ductless Fume Hoods
|  |  |  |  |
| Company | AirClean Systems | AirClean Systems | AirClean Systems | AirClean Systems |
| Item | AirMax® Total Exhaust Polypropylene Fume Hood | AC600 Series Ductless Chemical Fume Hoods | Polypropylene Laboratory Hoods - Folding Sash | Polypropylene Total Exhaust Fume Hoods |
| Citations | | | | |
| Catalog Number | AC3030TE / AC4030TE / AC5030TE / AC6030TE / AC8030TE | AC632A / AC632TA / AC632TAS / AC648A / AC648TA / AC648TAS | AC3000 / AC3036 / AC4000 / AC4036 / AC5000 / AC5036 / AC6000 / AC6036 | AC3000TE / AC4000TE / AC5000TE / AC6000TE |
| Price | | | | |
| Size(s) | 36, 48, 60, 72 and 96 in | 32 and 48 in | 36, 48, 60 and 72 in | 36, 48, 60 and 72 in |
| Type | Polypropylene | Ductless | Polypropylene | Polypropylene |
| Exterior Dimensions | varies with model | varies with model | varies with model | varies with model |
| Interior Dimensions | varies with model | varies with model | varies with model | varies with model |
| Depth | Inquire | 25 in. | Inquire | Inquire |
| Description | AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are manufactured from all-white, structural polypropylene. Polypropylene offers excellent chemical resistance. AirMax™ has a seamless design and allows for NO MORE RUST!
AirClean® Systems AirMax™ total exhaust polypropylene AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are manufactured from all-white, structural polypropylene. Polypropylene offers excellent chemical resistance. AirMax™ has a seamless design and allows for NO MORE RUST!
AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are standard bypass design. The standard bypass AirMax™ exhausts a constant volume of air, regardless of sash position.
A microprocessor controller monitors face velocity and displays the real-time airflow on the LCD screen in linear feet per minute.
Features - Flame-retardant polypropylene seamless interior
- Vertical sliding safety glass sash
- Variety of base cabinets available to compliment each AirMax™
- AirMax™ microprocessor controller
- Built-in vapor-proof fluorescent light
- Easy-access utilities panel for operation and maintenance
- All contact surfaces are constructed of polypropylene - “NO MORE RUST”!
- Flame-retardant polypropylene interior - higher temperature working range than fiberglass
- Non-hydroscopic - won’t absorb moisture
- Large volume spill basin with solid work surface
Safety Features - AirMax™ fume hoods have an advanced airfoil design that is important to the overall safety and performance of the fume hood. The rolled entry design incorporated into each AirMax™ hood prevents reverse flow and eddy currents from escaping the fume hood.
- AirMax™ exhaust hoods have a double sidewall construction which allows mounting of services and outlets on the posts.
- Containment of spills and heavy gases are easy with the AirMax™ total exhaust fume hood. A removable work surface exposes a spill basin that may be fitted with a drain for disposal of any spills.
- The rear baffle extends below the work surface to effectively remove any heavy gases or evaporation from a spill.
... Read More | Designed to provide a low cost chemical hood solution for protection of the operator and environment from toxic vapors, gases, fumes, and particulate. The AC600 Series ductless chemical workstation features the use of molded thermoplastics configured for a variety of common applications. Smaller in Designed to provide a low cost chemical hood solution for protection of the operator and environment from toxic vapors, gases, fumes, and particulate. The AC600 Series ductless chemical workstation features the use of molded thermoplastics configured for a variety of common applications. Smaller in size, it makes an excellent portable fume hood for the classroom or laboratory.
Standard Features - AirSafe™ automatic safety controller
- Integral base with deep spill lip
- No ducting required
- Minimal installation - plugs directly into a standard 110V or 220V electrical outlet Extremely quiet operation < 49db="" />
- All thermoplastic construction with application specific sash, base and enclosure material
- Available in “low-profile” or tall version 32” or 48” widths with nominal 24” depth
- UL, CSA and CE listed
Safety Features - The chemical fume hood filter and electronics are located above the work area, eliminating the chance of a chemical spill entering these sensitive areas.
- The brushless, sparkless motor is post-filter.
- The deep base effectively contains accidental spills.
- The low airflow alarm warns user both visually and audibly.
- Filter safety lockout to ensure correct filter replacement.
... Read More | AirClean® Systems polypropylene laboratory hoods allow for a wide range of applications. Each polypropylene hood is designed to accommodate up to 7 inches of filtration. By stacking a HEPA filter, followed by a bonded carbon filter, the operator can effectively remove both toxic particulate andAirClean® Systems polypropylene laboratory hoods allow for a wide range of applications. Each polypropylene hood is designed to accommodate up to 7 inches of filtration. By stacking a HEPA filter, followed by a bonded carbon filter, the operator can effectively remove both toxic particulate and chemical fumes. For high evaporation or multiple chemical applications, a full 7 inch stack of chemical filtration may be recommended.
Features - Polypropylene construction for excellent chemical resistant properties. The result - "NO MORE RUST" which allows for longer service compared to standard metal enclosures
- Wide range of activated carbon, impregnated chemisorptive, and HEPA filters for containment of virtually any toxic vapor, fume, gas, and particulate
- AirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, removing "dead spots" within the enclosure
- No ducting required
- Integral vapor-proof fluorescent lighting
- No installation costs. All AirClean® Systems bench-top hoods are shipped completely assembled (filters installed) and ready to use
- Available in 110V or 220V AC versions
- New 36" deep models available!
... Read More | AirClean® Systems economical single walled polypropylene fume hood is ideal for industrial applications where a ductless hood, workstation or enclosure is not appropriate and a full hood exhaust system is needed. These units are provided with a folding sash and vapor-proof fluorescent light. AirClean® Systems economical single walled polypropylene fume hood is ideal for industrial applications where a ductless hood, workstation or enclosure is not appropriate and a full hood exhaust system is needed. These units are provided with a folding sash and vapor-proof fluorescent light. The single walled design provides maximum work area for a fume hood of this size.
AirZone™ baffling within the total exhaust fume hood allows for a predictable and effective airflow pattern to capture toxic chemical fumes and vapors. The thermally fused seamless design provides a built-in work base that will effectively contain liquids and provide excellent chemical resistance.
Features - Polypropylene fume hood means corrosion-resistant construction
- Single wall design allows for maximum work space
- Economical solution for many industrial applications
- Low cost folding sash may be customized for various height requirements
- Available with single or dual exhaust duct connections.
- Internal baffling eliminates dead zones and provides for smooth airflow
- Seamless construction allows for easy cleaning
- Vapor-proof fluorescent light
- Optional airflow monitor for constant alphanumeric readout of airflow
- Polypropylene base cabinets available in vented and non-vented models
... Read More |
| Quantity | EA | EA | EA | EA |
| Get Quote | | | | |