| Size(s) | Inquire | 23.62, 35.4, 47.24, 59, and 70.8 in | Varies with model | 35.4, 47.2, 59, and 70.8 in | 23.62, 35.4, 47.24, 59, 70.8 in |
| Description | TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-1995 certified.
Structure: - Metal epoxy-coated paint
- The internal lining is made of 5 mm HPL
- Ceramic worktop is included – optional materials include stainless steel, polypropylene, epoxy, and HPL
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of epoxy-painted metal
- Air ventilation from both the top and rear panels
FEATURES - Basic control system is a 7” color touch screen controlling lighting and power outlets
- Optional upgrades to control systems:
- AFA system – includes a 7” screen with air velocity display and alarm
- VAV system includes a 10.1” screen with automatic air velocity control (installed and included VFD), temp & humidity display
- Active system has a 10.1” screen with an energy saver that includes automatic sash motion with the proximity sensing system
*An active system dramatically reduces energy costs - 800 lux LED lighting separated from the work area (option for explosion-proof light)
- Optional accessories such as taps, sinks, sockets, scaffolding, and an outdoor fan
- EN-14175, ASHRAE 110-1995, CE certified
... Read More | TopAir’s polypropylene Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
Our Ductless Fume Hood offers an air velocity display and alarm with a full Variable Air Volume (VAV) automatic speed adjustment to meet 100±20 fpm (0.5±0.1 m/s). This model is TopAir’s polypropylene Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
Our Ductless Fume Hood offers an air velocity display and alarm with a full Variable Air Volume (VAV) automatic speed adjustment to meet 100±20 fpm (0.5±0.1 m/s). This model is also equipped with a chemical VOC sensor and alarm to detect high levels of volatile compounds present in the filter for extra safety.
TopAir’s Ductless Fume Hoods can be customized to meet size requirements as needed.
Structure:- 8 mm welded polypropylene with high chemical resistance
- Built-in sealed polypropylene worktop or choice of epoxy, stainless steel, ceramic, or Trespa high pressure compact laminates (HPLs)
- 5 mm safety front glass window with sliding front sash with counterweight
- Side windows for better visibility
Features:- 10.1” color touchscreen display
- VAV with air flow alarm and display
- VOC sensor and alarm
- Chamber alert light (red) for critical alarms
- High efficiency quiet ECM fan
- 800 lux LED lighting separated from the work area
- Adjustable air velocity 100±20 fpm (0.5 ± 0.1 m/s)
- Convenient front access for filter replacement
- Variety of HEPA filters, carbon filters, and pre-filters
- 10” (250 mm) exhaust point collar for connection to external exhaust
- Optional: metal stand or polypropylene base cabinet
- Certifications: EN-14175 / ASHRAE 110-1995, CE
... Read More | TopAir’s Laminar Airflow Fume Hoods offer clean bench functionality. They are made of high-quality non-corrosive polypropylene with excellent chemical resistance.
The product is equipped with a dual airflow system: - Supply system with a pre-filter, HEPA filter and a fan that creates laminar down-
TopAir’s Laminar Airflow Fume Hoods offer clean bench functionality. They are made of high-quality non-corrosive polypropylene with excellent chemical resistance.
The product is equipped with a dual airflow system: - Supply system with a pre-filter, HEPA filter and a fan that creates laminar down-flow towards the working area.
- Exhaust system that needs to be connected to a ducting system with an outdoor fan. Both inflow and downflow (100% of the air) are channeled to the exhaust system.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – stainless steel optional.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation areas include perforations on the front and side area of the worktop and the grille at the rear.
Features: - 10.1” color touchscreen display
- VAV with air flow alarm and display
- Automatic laminar air velocity
- inflow is affected by the lab extracting system.
- automatic shutdown system for the down-flow when inflow system fails
- Clean bench functionality
- Cleanliness level – Class 100/ISO 5
- 800 lux LED lighting separated from the work area
- Includes polypropylene lower base cabinet
- Optional: sink/water tap/gas tap/ vacuum tap/electric sockets
- CE certified
... Read More | TopAir’s Valueline Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
This cost-effective benchtop ductless fume hood with an innovative, intelligent control system includes a 7” color touchscreen with airflow monitoring, alarm, integral polypropylene TopAir’s Valueline Ductless Fume Hood provides a safe environment for lab staff working with a variety of chemicals.
This cost-effective benchtop ductless fume hood with an innovative, intelligent control system includes a 7” color touchscreen with airflow monitoring, alarm, integral polypropylene worktop, a sliding front sash with counterweight, an environmentally friendly EC fan, and LED light.
A variety of filters can be supplied for maximum protection from most common chemical fumes.
TopAir’s Value-line Ductless Fume Hoods can be customized meet size requirements as needed.
Structure:- 8 mm welded Polypropylene with high chemical resistance
- Built-in sealed polypropylene worktop
- 5 mm safety front glass window with sliding front sash with counterweight
- Side windows for better visibility
Features- 7” color touchscreen display
- Airflow display and alarm
- 10 speed fan control
- Chamber alert light (red) for critical alarms
- Built-in sealed polypropylene worktop
- Tempered glass side windows and sliding front sash with counterweight
- 800 lux LED lighting
- Air velocity 100±20 fpm (0.5±0.1 m/s)
- Back access for filter replacement
- Variety of HEPA and carbon filters
- EC fan with 10 levels of speed adjustment
- 10” (250 mm) exhaust collar for connecting to external exhaust
- Optional: metal stand or polypropylene base cabinet
- Certification: CE
... Read More | Topair’s Weighing Station is designed for weighing powders and chemicals, and provides precise weighing data with up to 4 decimal places.
It also provides a safe work environment for lab staff working with acids and harsh chemicals.
The electrical and mechanical components are manufactured by leading Topair’s Weighing Station is designed for weighing powders and chemicals, and provides precise weighing data with up to 4 decimal places.
It also provides a safe work environment for lab staff working with acids and harsh chemicals.
The electrical and mechanical components are manufactured by leading global companies, such as AAF USA. The products are EN-14175 / CE / ASHRAE 110-1995 certified.
Advanced Operation System- Color 5" touch screen
- 10-speed fan
- Hour counter for filter
- Filter replacement alarm
TopAir’s weighing stations can be customized to the requirements of each client.
Features:Provides precise weighing data – up to 4 decimal placesPolypropylene structure with high chemical resistance7” control touch screen controlling lighting and powerBuilt-in sealed polypropylene worktop or choice of epoxy, stainless steel, ceramic, TrespaTempered glass sliding front windowHigh efficiency, quiet EC fanEco-friendly, cost-effective 800 LUX LED lighting separated from the work areaWind speed at 0.5±0.1 m/s, 100±20 FPMHEPA filter installedConvenient front access for filter replacementAir flow alarmOptional: No worktop, with independent table or optical table, standXL model with 2 internal filters is also availableEN-14175 / CE / ASHRAE 110-1995 certified... Read More |