Autoclave Sterilizer / Laboratory Autoclaves

Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.

Find, compare, and request a quote for laboratory autoclaves across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyAmerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.Amerex Instruments, Inc.
ItemHVE-50 Economical Top-Loading 50L Autoclave (Without Drying)HRH-110 Front-Loading 110L (Fully Automatic Drying)HV-110 Top-Loading 110L Autoclave (Without Drying)HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying)
Citations
(2)
Reviews
Catalog NumberHVE-50HRH-110HV-110HVA-85
Price
Temperature Range105C to 135C105C to 135C (Programmable)105C to 135C105C to 135C
Interior Dimensions(Diam x H) 11.8 x 28 in(Diam x D) 16.5 x 31.3 in(Diam x H) 16.5 x 31.3 in(Diam x H) 16.5 x 24.2 in
Exterior Dimensions(WxDxH) 20.1 x 20.8 x 40.9 in(WxDxH) 27.2 x 45.3 x 54.5 in(WxDxH) 26 x 25.6 x 46.5 in(WxDxH) 26 x 25.6 x 39.4 in
Chamber Volume50 L110 L110 L85 L
Pressure Range3 to 30 psi (gauge) (0.021 to 0.21 MPa)Inquire3 to 30 psi0 to 0.26 MPa
DescriptionSpace-saving design with lid opening upward.

Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.

Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.

Agar melting mode for melting
... Read More
Front-loading design

Fully automatic operation from start to finish with or without drying.

One-touch door closing lever opens and closes the door easily, surely and safely.

Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips,
... Read More
Space-saving design with lid opening upward.

Programmable auto-start for initiating a cycle up to 1 week later.

Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.

Automatic air purging by a microprocessor prevents over-pressurization
... Read More
Space-saving design with lid opening upward.

Standard built-in cooling fan for faster post- sterilization cooling.

Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.

Agar sterilization mode sterilizes agar, and
... Read More