Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
Find, compare, and request a quote for laboratory autoclaves across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |
| Company | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. |
| Item | HV-50 Top-Loading 50L Autoclave (Without Drying) | HV Series Portable Top-Loading Autoclaves | HV-25 Top-Loading 25L Autoclave (Without Drying) | HV-85 Top-Loading 85L Autoclave (Without Drying) |
| Citations | | | | |
| Reviews | | | | |
| Catalog Number | HV-50 | HV-25 / HV-50 / HV-85 / HV-110 | HV-25 | HV-85 |
| Price | | | | |
| Temperature Range | 105C to 135C | HV-25: 105 to 126°C
HV-50: 105 to 135°C | 105C to 126C | 105C to 135C |
| Interior Dimensions | (Diam x H) 11.8 x 28 in | Inquire | (Diam x H) 9.4 x 21.6 in | (Diam x H) 16.5 x 24.2 in |
| Exterior Dimensions | (WxDxH) 20 x 21 x 41 in | Inquire | (WxDxH) 19 x 18 x 37.4 in | (WxDxH) 26 x 25.6 x 39.4 in |
| Chamber Volume | 50 L | Inquire | 25 L | 85 L |
| Pressure Range | 3 to 22 psi | HV-25 / HV-50: 3 to 22 PSI gauge (0.02 to 0.148 MPa)
HV-85 / HV-110: 3 to 30 PSI (0.02 to 0.206 MPa) | 3 to 22 psi | 3 to 30 psi |
| Description | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More | The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization ofThe 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of agar, media, wastes, glassware, and fermentors, especially for the larger models.... Read More | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More |