Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
| | | | | |
Company | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. | Amerex Instruments, Inc. |
Item | HVA-110 Economical Top-Loading 110L Autoclave with Built-In Cooling Fan (Without Drying) | HA-300MD Top-Loading 50L Autoclave (Manual Drying) | HG-50 Top-Loading 50L Autoclaves (Without Drying) | HV-85 Top-Loading 85L Autoclave (Without Drying) | HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying) |
Reviews | | | | | |
Catalog Number | HVA-110 | HA-300MD | HG-50 | HV-85 | HVA-85 |
Price | | | | | |
Temperature Range | 105C to 135C | 105C to 126C | 105C to 135C | 105C to 135C | 105C to 135C |
Interior Dimensions | (Diam x H) 16.5 x 31.3 in | (Diam x H) 11.8 x 26.4 in | (Diam x H) 14.3 x 18.2 in | (Diam x H) 16.5 x 24.2 in | (Diam x H) 16.5 x 24.2 in |
Exterior Dimensions | (WxDxH) 26 x 25.6 x 46.4 in | (WxDxH) 17.3 x 20.5 x 42.1 in | (WxDxH) 19.7 x 27.2 x 35.0 in | (WxDxH) 26 x 25.6 x 39.4 in | (WxDxH) 26 x 25.6 x 39.4 in |
Chamber Volume | 110 L | 50 L | 50 L (Working Volume), 60 L (Actual Volume) | 85 L | 85 L |
Pressure Range | 0 to 0.26 MPa | 3 to 30 psi (gauge) (0.021 to 0.21 MPa) | Inquire | 3 to 30 psi | 0 to 0.26 MPa |
Description | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More | Top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles.
Deep chamber for accommodating fermentors and bioreactors.
Space-saving, stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory.
Top loading design is ideal for the sterilization of media and other liquids in tall flasks and bottles.
Deep chamber for accommodating fermentors and bioreactors.
Space-saving, stand-alone unit occupies minimal floor space and can fit conveniently into many locations in the laboratory.
Full-count sterilization guarantees sterilization at the preset temperature and time. Timer pauses if chamber temperature falls 1ºC below the preset temperature.
Liquid cycles with slow exhaust or natural cooling for liquids and solids without drying.
Drying cycle for glassware and other solid loads.
Additional drying cycle without re-sterilization.
Micro-processor controlled for precise sterilization.
Internal steam generator uses purified water to generate pure steam.
Audio/visual alarms and on-board diagnostics for rapid repair.... Read More | Automatic lid opening button replaces a foot pedal.
Automatic lid closing button closes and locks lid conveniently and safely.
New body design with a 50- or 80-liter chamber of larger diameter and shorter height.
Safety interlock senses pressure and temperature and prevents lid from openingAutomatic lid opening button replaces a foot pedal.
Automatic lid closing button closes and locks lid conveniently and safely.
New body design with a 50- or 80-liter chamber of larger diameter and shorter height.
Safety interlock senses pressure and temperature and prevents lid from opening when the chamber is pressurized, temperature is too high, and also during a cycle.
Programmable auto-start for running a cycle up to 99 hours later.
Efficient 15-liter steam condenser eliminates steam exhaust into the lab.
Over-flow lamp indicates that the drain bottle is full and ready to be emptied.
Built-in cooling fan for faster post-sterilization cooling and shorter completion time.
Selectable rate of steam venting after sterilization.
Programmable time for air removal before sterilization.
Large control and display panel improves functionality and shows the progress of the sterilization cycle.... Read More | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More |
Get Quote | | | | | |