Description | The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization ofThe 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of agar, media, wastes, glassware, and fermentors, especially for the larger models.... Read More | Front-loading design
Fully automatic operation from start to finish with or without drying.
One-touch door closing lever opens and closes the door easily, surely and safely.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, Front-loading design
Fully automatic operation from start to finish with or without drying.
One-touch door closing lever opens and closes the door easily, surely and safely.
Pre-vacuum cycle - vacuum pump removes air from the chamber when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilization.
Drying by heat and vacuum increases drying efficiency and reduces cycle times.
Additional drying mode for complete drying without having to run the sterilization cycle again.
Bacteria filter reduces re-contamination.
Lid safety interlock prevents lid from opening during a cycle, when the chamber is pressurized, or when the chamber temperature is above 97°C at which super-heated liquids might boil over when disturbed.
Door-closure sensor prevents a cycle from starting unless the door is properly closed.
Process display shows the program selected and the status of the sterilization cycle.
Chamber dimensions: 16.5” Diameter x 31.3” Depth
Chamber volume: 110 liters... Read More | Space-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurizationSpace-saving design with lid opening upward.
Programmable auto-start for initiating a cycle up to 1 week later.
Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust.
Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
In-process display shows status and progress of sterilization cycle.
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
Unique accessory: Floating sensor to monitor load temperature.
Sterilization timer is activated only when load temperature reaches set temperature.
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
Memory backup system retains user-programmed parameters even in case of power failure.... Read More | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More | Space-saving design with lid opening upward.
Fully automatic drying cycle for solid loads uses heat and vacuum for faster and more efficient drying.
Lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or when the temperature exceeds 97°C.
Vacuum pumpSpace-saving design with lid opening upward.
Fully automatic drying cycle for solid loads uses heat and vacuum for faster and more efficient drying.
Lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or when the temperature exceeds 97°C.
Vacuum pump removes air from the chamber, when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilziation.
One-touch lever to easily open and close chamber lid.
Liquid cycle for media and agar. Process display shows the program progress selected and status of the sterilization cycle.
Cycle for wastes and glassware without drying.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
HVP-50 size: 50 liters, 11.8" diameter, 28.0" height.... Read More |