Laboratory autoclaves sterilize laboratory equipment by using high temperatures and pressure to produce steam. Autoclaves are found in research labs, medical environments, dental offices, and anywhere else where microbial contamination is a primary concern. When loading an autoclave, it is important the instruments not be touching each other so the steam can access every surface point. Some things to consider when purchasing an autoclave sterilizer are how much equipment the machine can hold, the temperature and pressure range, and if cooling is an option.
| | |
Company | Amerex Instruments, Inc. | Amerex Instruments, Inc. |
Item | HV Series Portable Top-Loading Autoclaves | HVA-85 Economical Top-Loading 85L Autoclave with Built-In Cooling Fan (Without Drying) |
Citations | | |
Catalog Number | HV-25 / HV-50 / HV-85 / HV-110 | HVA-85 |
Price | | |
Temperature Range | HV-25: 105 to 126°C
HV-50: 105 to 135°C | 105C to 135C |
Interior Dimensions | Inquire | (Diam x H) 16.5 x 24.2 in |
Exterior Dimensions | Inquire | (WxDxH) 26 x 25.6 x 39.4 in |
Chamber Volume | Inquire | 85 L |
Pressure Range | HV-25 / HV-50: 3 to 22 PSI gauge (0.02 to 0.148 MPa)
HV-85 / HV-110: 3 to 30 PSI (0.02 to 0.206 MPa) | 0 to 0.26 MPa |
Description | The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization ofThe 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-contained, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of agar, media, wastes, glassware, and fermentors, especially for the larger models.... Read More | Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and Space-saving design with lid opening upward.
Standard built-in cooling fan for faster post- sterilization cooling.
Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
One-touch lever to easily open and close chamber lid.
Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
Door-closure sensor prevents a cycle from starting unless the door is closed properly.
In-process display shows the status and the progress of sterilization cycle.... Read More |