Calibration gas generators are used to mix calibration gasses for techniques such as GC or gas detector calibration and are capable of calibration gas generation at sub-ppm to % gas concentrations. Gas calibration equipment can be utilized to produce single calibration gasses as well as mixing multipoint gas calibrations. Oftentimes meeting requirements for various regulatory bodies such as NIST, gas calibration generators can automate the process of mixing trace concentration calibration gas. For laboratories requiring high ppm or % concentration calibration gas, ensure a sufficient flow rate is offered by the calibration gas generator. Calibration gas equipment typically has onboard screens for user input and to display real-time information, however, certain models also offer additional options such as PC interfacing for control and monitoring.
|  |  |  |  |
| Company | KIN-TEK Analytical, Inc. | KIN-TEK Analytical, Inc. | KIN-TEK Analytical, Inc. | KIN-TEK Analytical, Inc. |
| Item | FlexMixer™ Multi-Gas Blending/Diluting System | EcoFlex™ System | Gas Permeation Calibration Products | Span Pac I Industrial Gas Generator |
| Reviews | | | | |
| Catalog Number | FlexMixer Multi-Gas Blending/Diluting System | EcoFlex System | Gas Permeation Calibration Series | Span Pac I Industrial Gas Generator |
| Price | | | | |
| Description | KIN-TEK has been a leader in supplying gas calibration equipment for over 50 years. Expanding on many years of knowledge and experience, KIN-TEK introduces the FlexMixer™ Multi-Gas Blending/Diluting System that mixes or dilutes up to 4 separate gas feeds (or cylinder sources) to one Span Gas KIN-TEK has been a leader in supplying gas calibration equipment for over 50 years. Expanding on many years of knowledge and experience, KIN-TEK introduces the FlexMixer™ Multi-Gas Blending/Diluting System that mixes or dilutes up to 4 separate gas feeds (or cylinder sources) to one Span Gas output. Controlled by user friendly software installed on the user PC, the FlexMixer™ is an economical, lightweight, functional solution for a broad range of applications. The FlexMixer™ generates gas standards for multipoint gas analyzer calibration, fills test volumes for research purposes, or dilutes select gas sources. The FlexMixer™ can be customized to accommodate different types of gas input sources and/or premixed cylinders. Users easily create percent level (%) concentrations or trace concentration gas mixtures for storage or calibration.
Features:- Automated Gas Blending of Balance Gas and up to 3 Component Gases.
- 100+ preloaded gas configurations available, 20 user defined gas blends.
- Profile and Manual control modes.
- Create, control, and measure custom gas blends.
- Perform multi-point calibration of analyzers, sensors, detectors.
- Dilute existing cylinder sources
- User friendly software for a simplified solution with integrated safety shut off.
- Portability between labs or facilities with small footprint.
... Read More | The EcoFlex™ Permeation System is designed for creating trace concentration gas mixtures. Mixtures are produced by diluting the minuscule flow of vapor emitted by Trace Source™ permeation (or diffusion) tubes with a much larger flow of inert matrix gas, typically nitrogen or zero air. Mixtures The EcoFlex™ Permeation System is designed for creating trace concentration gas mixtures. Mixtures are produced by diluting the minuscule flow of vapor emitted by Trace Source™ permeation (or diffusion) tubes with a much larger flow of inert matrix gas, typically nitrogen or zero air. Mixtures contact only suitably inert materials, Teflon®, coated stainless steel, or glass.
The EcoFlex™ manual system is built on the same readily transportable platform as the microprocessor controlled FlexStream™ Base Module. The EcoFlex™, however, is a simple, stand-alone, non-expandable, single oven permeation system.
The EcoFlex™ holds the Trace Source™ Permeation Tube(s) at a constant temperature and introduces a small controlled flow of dilution gas over the tube. Pure component compound vapor emitted from the permeation tube(s) mixes with this small flow to form a ‘base’ concentration gas mixture. This base mixture then joins a larger main dilution flow to form the final mixture. The mixture concentration is set by adjusting that main dilution flow.
Permeation tubes of various emission rates are available for over 550 compounds. By choosing a tube suited to the application, mixtures having concentration from low ppb to over 1000 ppm can be generated and the concentration can then be adjusted over a 20:1 range. A single permeation tube, for instance, might be used for concentrations from 1 ppm in 250 cc/min or down to 50 ppb in 5 slpm. Using the mixture immediately after preparation eliminates storage loss.... Read More | Inquire | KIN-TEK Industrial Gas Standard Generators are used in industrial environments. These instrument systems use Trace Source™ permeation tubes to deliver calibration gas standards directly to your process GC, GC-MS, or any type of gas analyzer. KIN-TEK Gas Standard Generators provide the temperature KIN-TEK Industrial Gas Standard Generators are used in industrial environments. These instrument systems use Trace Source™ permeation tubes to deliver calibration gas standards directly to your process GC, GC-MS, or any type of gas analyzer. KIN-TEK Gas Standard Generators provide the temperature controlled environment for equilibration of the permeation tubes and carrier gas control for generating the desired concentrations.
Features:Single & dual oven models Concentration adjustable over 10:1 range High ppm to low ppb range Multi component mixtures (up to 16 compounds with 2-oven system) Simple to operate... Read More |
| Flow Rate | 0 to 5 sLpm | 0.25 to 5.0 standard liters per minute | 0.25 to 5.0 standard liters per minute | 0.25 to 5.0 standard liters per minute |
| Dimensions | (WxDxH) 11.5 x 9.63 x 6.25 in. (29.84 x 24.46 x 15.87 cm) | (WxDxH) 6 x 20 x 13.5 in | (WxDxH) 7 x 20 x 13.5 in. (18 x 51 x 34 cm) (depending on model) | (WxDxH) 24 x 12 x 24 in. |
| Power Supply | Inquire | Inquire | 115 VAC, 50/60 Hz, 2 A | Inquire |