| Company | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena |
| Item | multi N/C® Series TOC/TNb Analyzers | multi N/C 2300 | multi N/C 3300 | multi N/C 4300 UV | multi N/C pharma |
| Citations | | | | | |
| Catalog Number | multi N/C 3x00 | | | | |
| Price | | | | | |
| Measurement Mode(s) | TC, TIC, TOC, NPOC, POC, and TNb | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD); optional POC (particulate organic carbon) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional solids TC/TOC/TIC (no TNb) | TOC, NPOC, TC, TIC; optional TNb (chemiluminescence, CLD) for combustion models; multi N/C 2100S pharma: TN only for total protein determination |
| Oxidation Method | High temperature combustion / Wet chemical oxidation by UV radiation (254 nm+185 nm) /persulfate dependent on instrument configuration | Catalytic high-temperature combustion up to 950°C; optional catalyst-free oxidation up to 1300°C (solids with HT 1300 module) | Catalytic high-temperature combustion up to 950°C (liquids); catalyst-free oxidation up to 1300°C (solids, duo models) | UV wet chemical digestion (high-power UV reactor, 254 nm and 185 nm wavelengths); optional non-catalytic high-temperature combustion up to 1300°C for solids (HT 1300 module) | pharma UV: UV wet chemical digestion (254 nm + 185 nm, High Power Long Life UV reactor); pharma HT and 3100 pharma: thermocatalytic high-temperature combustion up to 950°C |
| Measuring Range | 0–30,000 mg/L C | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD) | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD); Solids: 0–100 wt-% | 0–10,000 mg/L C | pharma UV: 1 µg/L – 10,000 mg/L C; 3100 pharma: 4 µg/L – 30,000 mg/L C; 2100S pharma: 5 µg/L – 200 mg/L TN |
| Detection Limit | 1 µg/L C - 50 µg/L C dependent on instrument configuration | 50 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 4 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 1 µg/L C | pharma UV: 1 µg/L C (ultra-trace without persulfate); pharma HT: 4 µg/L C; 3100 pharma: 4 µg/L C; 2100S pharma: 5 µg/L TN |
| Sample Volume | 50–20,000 µL variable dependent on instrument configuration | 10–500 µL (direct injection by microliter syringe) | 50–1000 µL (standard); 50–3000 µL (3300 HS model) | 50–20,000 µL (flow injection) | pharma UV: up to 20 mL (flow injection); pharma HT: up to 3 mL (flow injection); 3100 pharma: up to 1 mL (ceramic valve, flow injection); 2100S pharma: 50–500 µL (direct syringe injection) |
| Measurement Accuracy | Inquire | RSD 2–3% | RSD 1–2% | 1–2% | Inquire |
| Measuring Time | Approx. 3–5 min for each parameter | 3–5 min/sample | 3–5 min/sample | 3–5 min/sample | Inquire |
| Description | multi N/C Series Robust and reliable for any TOC/TNb application - Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the multi N/C Series Robust and reliable for any TOC/TNb application - Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the Pharmaceutical Industry - Designed for pharmaceutical ultrapure water TOC analysis
- High-temperature combustion or UV oxidation, in compliance with FDA data integrity requirements (21 CFR Part 11)
multi N/C 4300 Series - Optimum sensitivity at TOC trace levels
- Short measuring times and highest oxidation power due to high-energy UV radiation at 2 wavelengths
- Economical operation thanks to long-lasting components and inexpensive reagents
- Time-saving automation functions for the ultrapure water range
- New intuitive software with live result display
multi N/C 3300 Series - Precise measurement of high and low TOC contents
- High robustness even for samples containing particles
- Optimized for high throughput analysis
- Versatile configuration and automation options
- New intuitive software with live results display
multi N/C 2300 Series - Compact and robust
- Optimal particle handling without sample carryover
- Suitable for the smallest sample volumes (injection volumes: 10 - 500 µl)
- Easy handling and optimized processes
- New intuitive software with live results display
... Read More | Inquire | Inquire | Inquire | Inquire |