A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present.
TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.
Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |
| Company | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena |
| Item | multi N/C® Series TOC/TNb Analyzers | multi N/C 2300 | multi N/C 4300 UV | multi N/C pharma |
| Citations | | | | |
| Catalog Number | multi N/C 3x00 | | | |
| Price | | | | |
| Measurement Mode(s) | TC, TIC, TOC, NPOC, POC, and TNb | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional solids TC/TOC/TIC (no TNb) | TOC, NPOC, TC, TIC; optional TNb (chemiluminescence, CLD) for combustion models; multi N/C 2100S pharma: TN only for total protein determination |
| Oxidation Method | High temperature combustion / Wet chemical oxidation by UV radiation (254 nm+185 nm) /persulfate dependent on instrument configuration | Catalytic high-temperature combustion up to 950°C; optional catalyst-free oxidation up to 1300°C (solids with HT 1300 module) | UV wet chemical digestion (high-power UV reactor, 254 nm and 185 nm wavelengths); optional non-catalytic high-temperature combustion up to 1300°C for solids (HT 1300 module) | pharma UV: UV wet chemical digestion (254 nm + 185 nm, High Power Long Life UV reactor); pharma HT and 3100 pharma: thermocatalytic high-temperature combustion up to 950°C |
| Measuring Range | 0–30,000 mg/L C | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD) | 0–10,000 mg/L C | pharma UV: 1 µg/L – 10,000 mg/L C; 3100 pharma: 4 µg/L – 30,000 mg/L C; 2100S pharma: 5 µg/L – 200 mg/L TN |
| Detection Limit | 1 µg/L C - 50 µg/L C dependent on instrument configuration | 50 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 1 µg/L C | pharma UV: 1 µg/L C (ultra-trace without persulfate); pharma HT: 4 µg/L C; 3100 pharma: 4 µg/L C; 2100S pharma: 5 µg/L TN |
| Sample Volume | 50–20,000 µL variable dependent on instrument configuration | 10–500 µL (direct injection by microliter syringe) | 50–20,000 µL (flow injection) | pharma UV: up to 20 mL (flow injection); pharma HT: up to 3 mL (flow injection); 3100 pharma: up to 1 mL (ceramic valve, flow injection); 2100S pharma: 50–500 µL (direct syringe injection) |
| Measurement Accuracy | Inquire | RSD 2–3% | 1–2% | Inquire |
| Measuring Time | Approx. 3–5 min for each parameter | 3–5 min/sample | 3–5 min/sample | Inquire |
| Description | multi N/C Series Robust and reliable for any TOC/TNb application - Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the multi N/C Series Robust and reliable for any TOC/TNb application - Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the Pharmaceutical Industry - Designed for pharmaceutical ultrapure water TOC analysis
- High-temperature combustion or UV oxidation, in compliance with FDA data integrity requirements (21 CFR Part 11)
multi N/C 4300 Series - Optimum sensitivity at TOC trace levels
- Short measuring times and highest oxidation power due to high-energy UV radiation at 2 wavelengths
- Economical operation thanks to long-lasting components and inexpensive reagents
- Time-saving automation functions for the ultrapure water range
- New intuitive software with live result display
multi N/C 3300 Series - Precise measurement of high and low TOC contents
- High robustness even for samples containing particles
- Optimized for high throughput analysis
- Versatile configuration and automation options
- New intuitive software with live results display
multi N/C 2300 Series - Compact and robust
- Optimal particle handling without sample carryover
- Suitable for the smallest sample volumes (injection volumes: 10 - 500 µl)
- Easy handling and optimized processes
- New intuitive software with live results display
... Read More | Inquire | Inquire | Inquire |