| Company | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena |
| Item | multi N/C 2300 | multi N/C 3300 | multi N/C® Series TOC/TNb Analyzers | multi X® 2500 AOX/TOX Analyzer |
| Citations | | | | |
| Catalog Number | | | multi N/C Series | multi X 2500 |
| Price | | | | |
| Measurement Mode(s) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD); optional POC (particulate organic carbon) | TC, TIC, TOC, NPOC, POC, and TNb | Microcoulometry, NDIR, for AOX, EOX, POX, TOC, TX/TOX |
| Oxidation Method | Catalytic high-temperature combustion up to 950°C; optional catalyst-free oxidation up to 1300°C (solids with HT 1300 module) | Catalytic high-temperature combustion up to 950°C (liquids); catalyst-free oxidation up to 1300°C (solids, duo models) | High temperature combustion / Wet chemical oxidation by UV radiation (254 nm+185 nm) /persulfate dependent on instrument configuration | Combustion |
| Measuring Range | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD) | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD); Solids: 0–100 wt-% | 0–30,000 mg/L C | AOX/ EOX/ POX/ TX/ TOX determination - up to 1,000 µg Cl absolute
TOC determination - up to 10,000 mg/l TOC |
| Detection Limit | 50 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 4 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 1 µg/L C - 50 µg/L C dependent on instrument configuration | AOX/ EOX/ POX/ TX/ TOX determination - 10 ng Cl absolute
TOC determination - 0.2 mg/l |
| Sample Volume | 10–500 µL (direct injection by microliter syringe) | 50–1000 µL (standard); 50–3000 µL (3300 HS model) | 50–20,000 µL variable dependent on instrument configuration | max. 100 µl for EOX extracts and TX for liquid samples max. 100 mg for TX in solid samples.
TOC determination max. 500 µl of the water sample |
| Measurement Accuracy | RSD 2–3% | RSD 1–2% | Inquire | Inquire |
| Measuring Time | 3–5 min/sample | 3–5 min/sample | Approx. 3–5 min for each parameter | AOX/EOX/TX: approx. 8 - 10 min depending on concentration and application
TOC: approx. 3 - 5 min depending on concentration and application |
| Description | Inquire | Inquire | multi N/C Series Robust and reliable for any TOC/TNbapplication
- Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the multi N/C Series Robust and reliable for any TOC/TNbapplication
- Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
- Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
- Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the Pharmaceutical Industry
- Designed for pharmaceutical ultrapure water TOC analysis
- High-temperature combustion or UV oxidation, in compliance with FDA data integrity requirements (21 CFR Part 11)
multi N/C 4300 Series
- Optimum sensitivity at TOC trace levels
- Short measuring times and highest oxidation power due to high-energy UV radiation at 2 wavelengths
- Economical operation thanks to long-lasting components and inexpensive reagents
- Time-saving automation functions for the ultrapure water range
- New intuitive software with live result display
multi N/C 3300 Series
- Precise measurement of high and low TOC contents
- High robustness even for samples containing particles
- Optimized for high throughput analysis
- Versatile configuration and automation options
- New intuitive software with live results display
multi N/C 2300 Series
- Compact and robust
- Optimal particle handling without sample carryover
- Suitable for the smallest sample volumes (injection volumes: 10 - 500 µl)
- Easy handling and optimized processes
- New intuitive software with live results display
... Read More | In environmental monitoring as well as in process and quality control, the determination of organic halogens which can be adsorbed by activated charcoal is very important for the evaluation of water and waste water. With the multi X® 2500, Analytik Jena provides a flexible, future-oriented system In environmental monitoring as well as in process and quality control, the determination of organic halogens which can be adsorbed by activated charcoal is very important for the evaluation of water and waste water. With the multi X® 2500, Analytik Jena provides a flexible, future-oriented system for sum parameter analysis that meets the requirements of every modern laboratory.
Features:- Very easy handling
- Plug-and-start technology
- Significantly reduced maintenance work
- Intelligent software package multiWin®
- Fast changeover between batch and column method
- User-friendly design ensures outstanding ease of use and efficiency
- High sample throughput in the vertical and horizontal mode
... Read More |
| Get Quote | | | | |