| Company | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena | Analytik Jena |
| Item | multi N/C 3300 | multi N/C 2300 | multi N/C 4300 UV | multi N/C pharma | multi X® 2500 AOX/TOX Analyzer |
| Citations | | | | | |
| Catalog Number | | | | | multi X 2500 |
| Price | | | | | |
| Measurement Mode(s) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD); optional POC (particulate organic carbon) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD) | TC, TIC, TOC, DOC, NPOC, NPOCplus; optional solids TC/TOC/TIC (no TNb) | TOC, NPOC, TC, TIC; optional TNb (chemiluminescence, CLD) for combustion models; multi N/C 2100S pharma: TN only for total protein determination | Microcoulometry, NDIR, for AOX, EOX, POX, TOC, TX/TOX |
| Oxidation Method | Catalytic high-temperature combustion up to 950°C (liquids); catalyst-free oxidation up to 1300°C (solids, duo models) | Catalytic high-temperature combustion up to 950°C; optional catalyst-free oxidation up to 1300°C (solids with HT 1300 module) | UV wet chemical digestion (high-power UV reactor, 254 nm and 185 nm wavelengths); optional non-catalytic high-temperature combustion up to 1300°C for solids (HT 1300 module) | pharma UV: UV wet chemical digestion (254 nm + 185 nm, High Power Long Life UV reactor); pharma HT and 3100 pharma: thermocatalytic high-temperature combustion up to 950°C | Combustion |
| Measuring Range | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD); Solids: 0–100 wt-% | 0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD) | 0–10,000 mg/L C | pharma UV: 1 µg/L – 10,000 mg/L C; 3100 pharma: 4 µg/L – 30,000 mg/L C; 2100S pharma: 5 µg/L – 200 mg/L TN | AOX/ EOX/ POX/ TX/ TOX determination - up to 1,000 µg Cl absolute
TOC determination - up to 10,000 mg/l TOC |
| Detection Limit | 4 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 50 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L | 1 µg/L C | pharma UV: 1 µg/L C (ultra-trace without persulfate); pharma HT: 4 µg/L C; 3100 pharma: 4 µg/L C; 2100S pharma: 5 µg/L TN | AOX/ EOX/ POX/ TX/ TOX determination - 10 ng Cl absolute
TOC determination - 0.2 mg/l |
| Sample Volume | 50–1000 µL (standard); 50–3000 µL (3300 HS model) | 10–500 µL (direct injection by microliter syringe) | 50–20,000 µL (flow injection) | pharma UV: up to 20 mL (flow injection); pharma HT: up to 3 mL (flow injection); 3100 pharma: up to 1 mL (ceramic valve, flow injection); 2100S pharma: 50–500 µL (direct syringe injection) | max. 100 µl for EOX extracts and TX for liquid samples max. 100 mg for TX in solid samples.
TOC determination max. 500 µl of the water sample |
| Measurement Accuracy | RSD 1–2% | RSD 2–3% | 1–2% | Inquire | Inquire |
| Measuring Time | 3–5 min/sample | 3–5 min/sample | 3–5 min/sample | Inquire | AOX/EOX/TX: approx. 8 - 10 min depending on concentration and application
TOC: approx. 3 - 5 min depending on concentration and application |
| Description | Inquire | Inquire | Inquire | Inquire | In environmental monitoring as well as in process and quality control, the determination of organic halogens which can be adsorbed by activated charcoal is very important for the evaluation of water and waste water. With the multi X® 2500, Analytik Jena provides a flexible, future-oriented system In environmental monitoring as well as in process and quality control, the determination of organic halogens which can be adsorbed by activated charcoal is very important for the evaluation of water and waste water. With the multi X® 2500, Analytik Jena provides a flexible, future-oriented system for sum parameter analysis that meets the requirements of every modern laboratory.
Features:- Very easy handling
- Plug-and-start technology
- Significantly reduced maintenance work
- Intelligent software package multiWin®
- Fast changeover between batch and column method
- User-friendly design ensures outstanding ease of use and efficiency
- High sample throughput in the vertical and horizontal mode
... Read More |