A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present. TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.

Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyAnalytik JenaAnalytik JenaAnalytik JenaAnalytik JenaAnalytik Jena
Itemmulti N/C 4300 UVmulti EA® 4000 for Macro-Elemental Analysismulti EA® 5100 for Micro-Elemental Analysismulti N/C pharmamulti N/C® Series TOC/TNb Analyzers
Citations
Reviews
Catalog Numbermulti EA 4000multi EA 5100multi N/C 3x00
Price
Measurement Mode(s)TC, TIC, TOC, DOC, NPOC, NPOCplus; optional solids TC/TOC/TIC (no TNb)TC, TOC, TIC, EC and BOCTOC, EOX or AOX/TOXTOC, NPOC, TC, TIC; optional TNb (chemiluminescence, CLD) for combustion models; multi N/C 2100S pharma: TN only for total protein determinationTC, TIC, TOC, NPOC, POC, and TNb
Oxidation MethodUV wet chemical digestion (high-power UV reactor, 254 nm and 185 nm wavelengths); optional non-catalytic high-temperature combustion up to 1300°C for solids (HT 1300 module)High-temperature combustionCombustionpharma UV: UV wet chemical digestion (254 nm + 185 nm, High Power Long Life UV reactor); pharma HT and 3100 pharma: thermocatalytic high-temperature combustion up to 950°CHigh temperature combustion / Wet chemical oxidation by UV radiation (254 nm+185 nm) /persulfate dependent on instrument configuration
Measuring Range0–10,000 mg/L C0 – 100 % C at 0.5 g sample or 500 mg C absolute
0 – 20 % S at 75 mg sample or 15 mg S absolute
0 – 10 % Cl at 100 mg sample or 10 mg Cl absolute
Carbon - 100 wt-% (organics) 10,000 mg/L (water), Nitrogen - 10,000 mg/L, Sulfur - 40,000 mg/L, Chlorine - 100,000 mg/Lpharma UV: 1 µg/L – 10,000 mg/L C; 3100 pharma: 4 µg/L – 30,000 mg/L C; 2100S pharma: 5 µg/L – 200 mg/L TN0–30,000 mg/L C
Detection Limit1 µg/L CCarbon - 3 ppm at 3 g sample weight or 10 µg C abs | Sulfur - 3 ppm at 3 g sample weight or 10 µg S abs. | Chlorine - 0.3 ppm at 3 g sample weight or 1 µg Cl abs.Carbon - 100 µg/L (organics) 200 µg/L (water), Nitrogen - 10 µg/L, Sulfur - 5 µg/L, Sulfur - 600 µg/L, Chlorine - 50 µg/L (“high sensitive”)pharma UV: 1 µg/L C (ultra-trace without persulfate); pharma HT: 4 µg/L C; 3100 pharma: 4 µg/L C; 2100S pharma: 5 µg/L TN1 µg/L C - 50 µg/L C dependent on instrument configuration
Sample Volume50–20,000 µL (flow injection)InquireLiquids: 1 – 500 µL, LPG: 1 – 50 µL, Gasses: 1 – 100 mLpharma UV: up to 20 mL (flow injection); pharma HT: up to 3 mL (flow injection); 3100 pharma: up to 1 mL (ceramic valve, flow injection); 2100S pharma: 50–500 µL (direct syringe injection)50–20,000 µL variable dependent on instrument configuration
Measurement Accuracy1–2%InquireInquireInquireInquire
Measuring Time3–5 min/sampleC/S determination (simultaneous or separate): at least 3 minutes, Cl determination: 3 - 10 minutesApprox. 3 – 5 min (V) C/N/S, 3 – 8 min C/N/S (H) and Cl (V/H)InquireApprox. 3–5 min for each parameter
DescriptionInquireThe multi EA® 4000 offers precise and reliable environmental analysis and is incredibly easy to use. It guarantees you the fully automated determination of the environmentally relevant parameters TC, TOC, TIC, EC and BOC in soil, sediments, waste, minerals and other inorganic solids.

Features:
  • For
... Read More
The multi EA® 5100 is extremely versatile: The determination of carbon, nitrogen, sulfur and chlorine is only a small part of what it can do. TOC, EOX or AOX/TOX analyses are further areas easily covered by the multi EA® 5000. This makes it a universal talent to be used in various fields.

Features:
... Read More
Inquiremulti N/C Series Robust and reliable for any TOC/TNb application
  • Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
  • Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
  • Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the