Total Organic Carbon Analyzer (TOC Analyzers)

A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present. TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.

Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyToray EngineeringToray EngineeringToray Engineering
ItemTOC-210 Series Automatic TOC AnalyzerTOC-200 Series Automatic TOC AnalyzerTOC-250L Desktop TOC Analyzer
Price
Measurement Mode(s)Online TOC, process monitoring, discharge monitoringOnline TOC, Offline TOCTC, NPOC, IC
Oxidation MethodLow-temperature sealed combustion at 650°C (optional high-sensitivity NDIR)Low-temperature sealed combustion at 650°C (NDIR detection)Sealed combustion (low-temperature catalytic)
Measuring Range0–100 mg/L (low-range, high sensitivity option); wider ranges available0–5 to 1,000 mg/L; optional 0–150 to 3,000 mg/L0–2 to 2,000 mgC/L (TC, NPOC, IC); up to 40,000 mgC/L by dilution
Detection LimitInquireInquire<0.05 mgC/L (standard); <0.02 mgC/L (high sensitivity)
Sample Volume30 µL (low-concentration range, optional NDIR)InquireInquire
Measurement AccuracyInquire±2% FS or ±0.15 mg/L (whichever is greater)±2% FS or ±0.05 mgC/L (whichever is greater)
Measuring TimeInquire4 min (TC); 5 min (TOC)~4.5 min (excluding preprocessing and cleaning)