Total Organic Carbon Analyzer (TOC Analyzers)

A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present. TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.

Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyAnalytik JenaAnalytik JenaAnalytik JenaAnalytik Jena
Itemmulti N/C® Series Analytical Systemsmulti EA® 4000 for Macro-Elemental Analysismulti EA® 5100 for Micro-Elemental Analysismulti X® 2500 AOX/TOX Analyzer
Citations
(2)
Reviews
Catalog Numbermulti N/Cmulti EA 4000multi EA 5100multi X 2500
Price
Measurement Mode(s)TC, TIC, TOC, NPOC, POC, and TNbTC, TOC, TIC, EC and BOCTOC, EOX or AOX/TOXMicrocoulometry, NDIR, for AOX, EOX, POX, TOC, TX/TOX
Oxidation MethodHigh temperature combustion / Wet chemical oxidation by UV radiation (254 nm+185 nm) /persulfate dependent on instrument configurationHigh-temperature combustionCombustionCombustion
Measuring Range0–30,000 mg/L C0 – 100 % C at 0.5 g sample or 500 mg C absolute
0 – 20 % S at 75 mg sample or 15 mg S absolute
0 – 10 % Cl at 100 mg sample or 10 mg Cl absolute
Carbon - 100 wt-% (organics) 10,000 mg/L (water), Nitrogen - 10,000 mg/L, Sulfur - 40,000 mg/L, Chlorine - 100,000 mg/LAOX/ EOX/ POX/ TX/ TOX determination - up to 1,000 µg Cl absolute
TOC determination - up to 10,000 mg/l TOC
Detection Limit1 µg/L C - 50 µg/L C dependent on instrument configurationCarbon - 3 ppm at 3 g sample weight or 10 µg C abs | Sulfur - 3 ppm at 3 g sample weight or 10 µg S abs. | Chlorine - 0.3 ppm at 3 g sample weight or 1 µg Cl abs.Carbon - 100 µg/L (organics) 200 µg/L (water), Nitrogen - 10 µg/L, Sulfur - 5 µg/L, Sulfur - 600 µg/L, Chlorine - 50 µg/L (“high sensitive”)AOX/ EOX/ POX/ TX/ TOX determination - 10 ng Cl absolute
TOC determination - 0.2 mg/l
Sample Volume50–20,000 µL variable dependent on instrument configurationInquireLiquids: 1 – 500 µL, LPG: 1 – 50 µL, Gasses: 1 – 100 mLmax. 100 µl for EOX extracts and TX for liquid samples max. 100 mg for TX in solid samples.
TOC determination max. 500 µl of the water sample
Measuring TimeApprox. 3–5 min for each parameterC/S determination (simultaneous or separate): at least 3 minutes, Cl determination: 3 - 10 minutesApprox. 3 – 5 min (V) C/N/S, 3 – 8 min C/N/S (H) and Cl (V/H)AOX/EOX/TX: approx. 8 - 10 min depending on concentration and application
TOC: approx. 3 - 5 min depending on concentration and application
Descriptionmulti N/C Series Robust and reliable for any TOC/TNbapplication
  • Reliable analysis of TC, TIC, TOC, NPOC, POC, and TNb
  • Guaranteed compliance with standards (e.g. DIN 1484, 15936, 12260...)
  • Accurate results even with complicated matrices
New High-performance TOC/TNb Analysis tailored for the
... Read More
The multi EA® 4000 offers precise and reliable environmental analysis and is incredibly easy to use. It guarantees you the fully automated determination of the environmentally relevant parameters TC, TOC, TIC, EC and BOC in soil, sediments, waste, minerals and other inorganic solids.

Features:
  • For
... Read More
The multi EA® 5100 is extremely versatile: The determination of carbon, nitrogen, sulfur and chlorine is only a small part of what it can do. TOC, EOX or AOX/TOX analyses are further areas easily covered by the multi EA® 5000. This makes it a universal talent to be used in various fields.

Features:
... Read More
In environmental monitoring as well as in process and quality control, the determination of organic halogens which can be adsorbed by activated charcoal is very important for the evaluation of water and waste water. With the multi X® 2500, Analytik Jena provides a flexible, future-oriented system ... Read More
Get Quote

Articles