Description | The Laser Scattering Particle Size Distribution Analyzer Partica LA-960V2 is the latest evolution in the LA series that advances scientific knowledge for tomorrow's world through intuitive software, unique accessories, and high performance.
Advanced Detector Design
The number of detectors, The Laser Scattering Particle Size Distribution Analyzer Partica LA-960V2 is the latest evolution in the LA series that advances scientific knowledge for tomorrow's world through intuitive software, unique accessories, and high performance.
Advanced Detector Design
The number of detectors, angular range, and layout each contribute to overall system performance.
Superior Instrument-to-Instrument Precision
The LA-960V2 is designed and built to provide the same experience regardless of manufacture date, operator skill, or geographic location. Achieve unmatched instrument agreement without the hassle of correlation.
Automatic Laser Alignment in Seconds
Always make perfect measurements with computer-controlled laser alignment. The alignment process is finished in only a few seconds with HORIBA's innovative approach.
Guaranteed Accuracy and Precision
The LA-960V2 is a highly refined particle size analyzer capable of accurately measuring NIST-traceable size standards within 0.6% of specification. Fully compliant with ISO 13320 recommendations regarding the measurement of materials on the D10, D50, and D90.... Read More | This highly advanced analyzer solves the mysteries of the nano-world. The nanoPartica SZ-100V2 analyzes the three parameters that characterize nanoparticles in a single device: particle size, zeta potential, and molecular weight.
- Particle Size Measurement Range 0.3 nm to 10 µm
The SZ-100V2 This highly advanced analyzer solves the mysteries of the nano-world. The nanoPartica SZ-100V2 analyzes the three parameters that characterize nanoparticles in a single device: particle size, zeta potential, and molecular weight.
- Particle Size Measurement Range 0.3 nm to 10 µm
The SZ-100V2 Series measures particle size and particle distribution width by dynamic light scattering (DLS).
Analysis across a wide range of sample concentrations: Measurement of samples ranging from low ppm-order concentrations to high-concentration samples in double-digit percentages is possible. Accepts commercially available sampling cells. Analysis of small-volume samples is also possible.
- Zeta Potential Measurement – 500 to + 500 mV
Analysis of sample volumes as small as 100 µL using HORIBA-developed microelectrophoresis cells. Use the value of zeta potential to predict and control dispersion stability. High zeta potential magnitudes indicate a stable dispersion, useful for formulation work.
- Molecular weight 1 × 103 to 2 × 107 Da
Absolute molecular weight (Mw) and the second virial coefficient (A2) are obtained by performing static light scattering measurement as a function of sample concentration and preparing Debye plots." ... Read More | HORIBA's LA-350 Laser Diffraction Particle Size Distribution Analyzer is the ideal combination of performance, price, and footprint. The LA-350 excels in applications as diverse as slurries, minerals, and paper chemistry. Based on the advanced optical design of previous LA-series analyzers, the LA-HORIBA's LA-350 Laser Diffraction Particle Size Distribution Analyzer is the ideal combination of performance, price, and footprint. The LA-350 excels in applications as diverse as slurries, minerals, and paper chemistry. Based on the advanced optical design of previous LA-series analyzers, the LA-350 strikes a harmonious balance between high functionality, easy operation, low maintenance, and cost-effectiveness.
- Range
0.1 - 1,000 µm which matches the widest range of applications with a performance equivalent to many other full-range systems.
- Compact Size
Crowded lab? Multiple locations? The compact size preserves bench space and makes it possible to transport the instrument to different locations within a facility or ship it to remote locations for on-site testing where it is not practical to purchase an analyzer.
- Fast Analysis
The highly refined optical design and algorithm provide measurement results in three easy steps: click, add sample, and review data. Data can be obtained in as little as ten seconds.
- Powerful Software
The LA-350 uses the same fully featured software package as our other LA-series analyzers, providing various statistical measures, data analysis, and presentation tools.
- Ease of Use
With automatic alignment, a built-in ultrasonic system for sample dispersion, and a powerful pumping system, combined with the automation features of the software, sample analysis on the LA-350 is extremely easy and straightforward. Sample analysis can be a one-button. ... Read More | The ViewSizer 3000 features simultaneous measurement with three lasers to collect the most accurate distribution and concentration information over a wide range of sizes within the same sample. Where the signal from a particle is too bright and saturates the detector from one laser, the software The ViewSizer 3000 features simultaneous measurement with three lasers to collect the most accurate distribution and concentration information over a wide range of sizes within the same sample. Where the signal from a particle is too bright and saturates the detector from one laser, the software automatically uses data from a lower-power laser to ensure the most accurate size and concentration information. On the other hand, when scattering from one laser is too weak for detection, the software uses data from a higher-power laser to accurately track the particle. This is why the ViewSizer 3000 is preferred over traditional NTA in the CMP, nanobubbles, microplastics, biomaterials, and applications where size and concentration for wide size distribution (polydisperse) is needed.... Read More |
Light Source | Red solid state 5 mW laser diode (650 nm), Blue solid state 3 mW LED (405 nm) | Diode-pumped frequency-doubled laser (532 nm, S2 / Z2 10 mW, HS2 / HZ2 100 mW)
Detectors: Photomultiplier tubes (PMT) | Laser diode 5mW, λ=650nm | 445nm Blue Diode Laser (350mW), 520nm Green Diode Laser (60mW), 635nm Red Diode Laser (35mW) |