| Description | MET ONE 7000 Remote Air Particle Counter Overview
The MET ONE 7000 provide high accuracy non-viable particle monitoring for cGMP/FDA compliance. Stainless steel wash-down resistant enclosure and VHP tolerant optics protect the instrument while ISO 21501 certified calibration assures accurate MET ONE 7000 Remote Air Particle Counter Overview
The MET ONE 7000 provide high accuracy non-viable particle monitoring for cGMP/FDA compliance. Stainless steel wash-down resistant enclosure and VHP tolerant optics protect the instrument while ISO 21501 certified calibration assures accurate continuous monitoring in aseptic and sterile pharmaceutical production environments. - Rugged design for cleanrooms with industry leading quality & reliability
- Stainless VHP, wash-down and chemically tolerant NEMA 4X enclosures
- Built-in flow sensor for CFR21 data accuracy and reliability
- Particle size 0.5µm and 5µm sensitivity at 0.1cfm or 1.0cfm flow rates
- Long life laser diode for guaranteed continuous monitoring
- Easy to integrate with any facility monitoring system
- Open architecture design to communicate seamlessly with your system
- Pulse, Serial Modbus, Ethernet, Wireless and Analog options
Features
Rugged design for cleanroom use - Stainless VHP, wash-down and chemically tolerant NEMA 4X enclosures.
Industry leading particle counting on-line reliability - ISO 21501 compliant with built-in flow sensor for CFR21 data accuracy and reliability.
Flexibility - Flexible particle count size in 0.5um and 5um sensitivity at 0.1cfm or 1.0cfm flow rates.
Industry leading quality and reliability - Long life laser diode for guaranteed continuous monitoring.
... Read More | HIAC 9703+ Pharmaceutical Particle Counter Overview HIAC 9703+ liquid sampler and PharmSpec Software for Parenteral Drug Final Product Testing to USP<787>, <788> & EP2.9.19 PharmSpec Software works with the HIAC 9703+ liquid particle counter system to test parenteral products for sub HIAC 9703+ Pharmaceutical Particle Counter Overview HIAC 9703+ liquid sampler and PharmSpec Software for Parenteral Drug Final Product Testing to USP<787>, <788> & EP2.9.19 PharmSpec Software works with the HIAC 9703+ liquid particle counter system to test parenteral products for sub-visible particle content using light obscuration in accordance with USP<787>, <788> and EP 2.9.19. Flexible calibration at multiple flow rates improves ease of sampling for varying sample viscosities and volumes. Ease of use and data integrity are prioritized in PharmSpec with features such as login credentials controlled by Microsoft Active Directory, multi-level user rights, automated pass/fail compendial reporting, comprehensive audit trail, and auto-flush routines for improved walkaway operation. In addition to the built-in compendial test routines, user-defined SOPs can be programmed into the counter using PharmSpec Software’s Procedure Builder. - PharmSpec software is 21 CFR Part 11 ALCOA compliant
- Secure database is either sited on the local pc operating the HIAC 9703 sampler, or sited remotely on a networked server
- Periodic database backup can be selected for additional database security
- Specially designed vial clamp holds sample in place and small-bore sampling probe enables full application of USP<787> for protein based drug products, such as vaccines
HIAC 9703+ Liquid Particle Counter Features Applications - Small volume injectable (SVI)
- Large volume injectable (LVI)
- Research & development
- Troubleshooting
- Stability testing
Sample management - Instant particle contamination notification
- Small vial holder & tare volume conserves costly samples
- Configurable flow rates & interchangeable sensors for 0.5 µm - 600 µm particle size detection
- Interchangeable sample probes & syringes
Software - Program custom SOPs to eliminate manual counter configuration and pass/fail calculations
- Multi-level security for 21 CFR Part 11 compliance
- Automatic database backup & recovery loss feature protects valuable results and data
Support - Expert SOP & IQ/OQ validation services available
- Routine onsite service available for maximum uptime
- ISO 21501 compliant calibrations
... Read More | MET ONE Hand Held Air Particle Counter (HHPC) Overview MET ONE HHPC+ Series handheld particle counters allow easy ISO Class 5 to 7 monitoring in hard-to-reach places. Lightweight with a high-resolution display, these handheld counters are ideal for routine monitoring of controlled environments and MET ONE Hand Held Air Particle Counter (HHPC) Overview MET ONE HHPC+ Series handheld particle counters allow easy ISO Class 5 to 7 monitoring in hard-to-reach places. Lightweight with a high-resolution display, these handheld counters are ideal for routine monitoring of controlled environments and mini-environments, easy filter leak troubleshooting for particle-contamination issues, spot-checking critical areas, and targeting particle generation within process equipment. - ISO 14644-1 industry standard
- CFR 21 Part 11 compliance enabled
- 0.3 μm - 10.0 μm particle detection
- 2-6 channel detection
- Single-hand operation
- PC access to particle counting data via Ethernet, USB, or cable for data transfer options
Features Standards - ISO 14644-1 Class 5 (FED STD Class 100 or higher) compliant sampling
- Counting efficiency to ISO 21501-4
- Zero count level to JIS B9921
Data Management - On-the-spot process profiling for fast particle event tracking
- Easy network connectivity for 21 CFR Part 11 compliance
- Store up to 10,000 records
- Convenient charge cradle for access to particle counting data via Ethernet or USB cable
- Data download via Ethernet
- Connectivity through USB and memory card
Ergonomic Design - Easy-to-read high resolution display
- Fully configurable display
- Slim & lightweight design (0.7 kg) for single-hand use
Applications - Routine monitoring in high-tech manufacturing & GMP-regulated cleanrooms
- Particle contamination troubleshooting in critical processing areas
- Spot checking & troubleshooting in mini-environments & workstations
... Read More | MET ONE R4800 and R4900 Remote Air Particle Counters Overview
The MET ONE R4800 and R4900 series remote air particle counters are affordable, reliable and provide accurate data in particle monitoring systems. A compact design with flexible sizing, flow rate and communication options address the MET ONE R4800 and R4900 Remote Air Particle Counters Overview
The MET ONE R4800 and R4900 series remote air particle counters are affordable, reliable and provide accurate data in particle monitoring systems. A compact design with flexible sizing, flow rate and communication options address the specific needs of cleanroom operations in pharmaceutical, semiconductor, hard disk drive and flat panel display industries.
Features
Easy Integration - MET ONE R4800 series remote air particle counters use standard RS-485 serial communications
- MET ONE R4900 series remote air particle counters use industry standard 4-20mA interface
- Stainless steel enclosure compatible with most process environments
- Compact size for easy mounting with a vacuum source, DC power & communication line
Data Management - MET ONE R4800 & R4900 counters respond to simple ASCII command instructions, including start, stop and report counts, send location number, etc.
- Reporting data includes counter status & particle counts in two size ranges
- Multiple display options via continuous monitoring feature (Particle Vision® Online & CIMScan® software
Operation - User-programmed alarm level detects high counts on first channel triggering an alarm
- Auto alarm reset at start of the next count cycle
- Long-life laser technology for superior performance & extended service life
- No fan allows proximate placement to sensitive processing areas
Flexible - Sensitivity ranges of 0.5um & flow rates of 1.0 cfm
- Onboard status indicator sets signal at connector for alarm Stay resident RS-485 configuration programming (count/hold times, alarm level/delay & scaling) maintained through power cycles
- Sensor resistant to vaporous hydrogen peroxide (VHP)
... Read More | Multisizer 4e Coulter Counter Overview The Multisizer 4e particle sizer and counter is the most accurate and flexible particle characterization device available, boasting an unparalleled sizing range of 0.2 - 1600 μm. The new 10 μm Aperture allows users to study sub-cellular and micro- Multisizer 4e Coulter Counter Overview The Multisizer 4e particle sizer and counter is the most accurate and flexible particle characterization device available, boasting an unparalleled sizing range of 0.2 - 1600 μm. The new 10 μm Aperture allows users to study sub-cellular and micro-particles as small as 200 nm, while the advanced noise reduction system for small apertures improves measurement accuracy. Generated data are processed using patented digital pulse processing technology and can be saved and later re-analyzed. This technology provides ultra high resolution and accuracy unattainable through any other technologies: detection of 1 particle in 1 ml of a sample with the optimal instrument configuration. Analysis results are not dependent on particle shape, structure, or optical properties. It uses the Coulter principle to detect particles via electrical zone sensing, regardless of the particle’s nature or optical properties. This makes it an ideal tool for detecting and counting a wide variety of particles, such as: - Mammalian cells
- Bacteria
- Yeast
- Abrasives
- Toner particles
- Cell aggregates
- Spheroids
- Large protein aggregates
Features Versatility - Aperture sizes from 10 µm - 2000 µm in diameter for current & future needs
- Multiple aperture options & data overlay capability for analyzing complex samples over wide particle size distribution
Sample Detection - Analyze materials in aqueous or non-aqueous solvents
- Ideal for biological or non-biological samples
- Detect particles regardless of material type or optical properties
Rapid Particle Counting - Typical sampling rates up to 10,000 counts per second
- Detect & count particles from 0.2 µm - 1600 µm in diameter
- Sample volumes as small as 5 mL
Data Management - Digital pulse data can be stored & re-analyzed as needed
- CFR 21 Part 11 compliant software for audit control & security
- Variety of calibration beads & V-check validation controls
... Read More |