| Detector(s) | FID, FPD, BID, ECD, TCD, FTD/NPD) | Quadrupole mass spectrometer | FID, TCD, ECD, FPD, FTD, BID | GCMS, FID, FPD, TCD, ECD, FTD | SCD |
| Description | Nexis GC-2030 offers a modern approach to a classic chromatographic technique. Designed with the user in mind, innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level.
Features/benefits - Faster ROI with versatile, expandable
Nexis GC-2030 offers a modern approach to a classic chromatographic technique. Designed with the user in mind, innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level.
Features/benefits - Faster ROI with versatile, expandable configurations – allows for up to three analytical lines for greater productivity or for the versatility of more analyses to be packaged into one GC
- Reduced operating costs with Eco mode – optimizes the use of carrier gas such as helium and reduces electricity use when idle
- Improved workflow with touch-panel interface and remote communications – ensures easy monitoring of the system’s operating status
- Increased productivity with tool-free column installation and inlet maintenance
- Optional, built-in sensor to monitor real time levels of hydrogen in the oven
Further enhancing productivity is LabSolutions workstation software that fully integrates LC and GC functionality. It offers both easy operability and extensive functionality. This includes a new data browser, convenient for comparing multiple sets of data simultaneously, and a Quick-Batch Function that simplifies the tedious process of creating injection sequences.... Read More | Shimadzu's Comprehensive GC-MS (GCxGC-MS) System is comprised of a combination of our fast scanning, high-sensitivity quad GCMS-QP2010Ultra and the Zoex Corporation series of modulators, ZX-1 or ZX-2. The QP2010Ultra is the only quadrupole mass spectrometer on the market that scans fast enough to Shimadzu's Comprehensive GC-MS (GCxGC-MS) System is comprised of a combination of our fast scanning, high-sensitivity quad GCMS-QP2010Ultra and the Zoex Corporation series of modulators, ZX-1 or ZX-2. The QP2010Ultra is the only quadrupole mass spectrometer on the market that scans fast enough to fully characterize the 100msec to 600msec peaks created by the modulation process. More economically priced than a TOF-MS, the quadrupole-MS has the added capability of Chemical Ionization and Negative Chemical Ionization for molecular ion spectral analysis and electrophyllic compound selectivity. The spectra generated by quad-MS are easily matched by the standard commercially available libraries such as the NIST, Wiley and FFNSC.
This system is available in a variety of configurations for complete control of your analysis. A second, full function, GC oven, with heated transfer line, can be added to the GCMS system that will allow separate temperature control of the first and second dimensional columns. It is also possible to incorporate our line of Advanced Capillary Flow products such as detector splitting packages, deans switching and backflush kits.
Features - Separation of Overlapping Peaks
- Image Patterns Show Compound Structure
- Data Analysis Software, GC Image
... Read More | Shimadzu’s Nexis GC-2060 gas chromatograph has been designed to maximize uptime, streamline workflows and improve laboratory efficiency. Delivering enhanced support for both routine and evolving analyses, the Nexis GC-2060 is designed for research and development and quality control analyses across Shimadzu’s Nexis GC-2060 gas chromatograph has been designed to maximize uptime, streamline workflows and improve laboratory efficiency. Delivering enhanced support for both routine and evolving analyses, the Nexis GC-2060 is designed for research and development and quality control analyses across a wide range of applications, including energy, chemicals, food, environmental testing and pharmaceuticals.
Features:
- Flame Ionization Detector (FID) with sensitivity enhanced by ~20 % over previous models and a minimum detection limit of 1.0 pgC/sec. In addition, it is the world’s first multi-mode FID, equipped with Hy/Ox and Hy/Air modes for the flexible selection of detector gases.
-
Thermal Conductivity Detector (TCD) with 25% improved detection limit, with a minimum detectable quantity of 300 pg/mL. This redesigned TCD uses single-?lament technology to significantly reduce start-up time. This TCD also stabilizes quickly and delivers accurate, repeatable results for a variety of gas and inorganic analyses.
-
Multimode Injection (MMI) unit featuring five distinct injection modes for versatility that allows a single GC to accommodate a wide range of analytical needs. The Nexis GC-2060 MMI supports split/splitless; programmable temperature vaporization (PTV); direct injection; large-volume injection (LVI); and thermal desorption/extraction injections in a single module.
-
Proprietary injection unit insulation delivers excellent temperature stability plus rapid heating and cooling, cutting wait times and keeping your lab running ef?ciently.
-
Enhanced expandability that maintains the same instrument footprint as previous models while increasing the number of pretreatment units, sample injection ports and detectors that operators can install.
-
Highly flexible system configurations tailored to diverse needs, such as parallel operation with dual-line analysis using the same setup, multi-application coverage with a single GC and high-speed analysis.
-
Automatic Eco-Operation function that learns analytical patterns from operating history and performs optimal eco-friendly operation. The system delivers maximum performance during analysis and automatically switches to energy-saving (Eco Idling) mode during standby.
-
Easy maintenance with on-demand support and troubleshooting.
Multiple design functions simplify operation for users of all skill levels. These functions include:
- One-touch injection unit access
-
Tool-free column installation
-
Automated startup and shutdown
-
Automated column conditioning
-
Precise control of the oven cooling rate
... Read More | The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance. Multi-Dimensional GC/GCMS System: A multi-dimensional GC/GCMS system performs separation using two columns that have different characteristics. The system has a mechanism in which the components that are insufficiently separated in the first column they pass through (the "1st column") are introduced ("heart-cut") to a second, different column (the "2nd column"). This enables analysis with a level of separation that cannot be attained in conventional single-column analysis. Outstanding retention time stability : In the past, samples have been introduced to columns using the switching mechanism known as Deans-switching. However, this system results in such problems as a reduced recovery rate and fluctuations in the retention time. The MDGC/GCMS-2010 system incorporates multi-Deans switching, a new mechanism that significantly reduces the likelihood of fluctuations in the retention times of eluted components, even if switching is performed several times. A Wide Variety of Optional Systems : In addition to GCMS, various other detectors, such as an FID or FPD, can be used with the MDGC/GCMS-2010. For example, a headspace sampler and thermal desorption system can be connected and controlled as a pretreatment system. When not using the MDGC/GCMS-2010 as an MDGC system, it is possible to use the GC and GCMS components as independent systems by changing the column and detector connections. ... Read More | The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include: - Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within
The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system offering enhanced sensitivity and reliability, excellent maintainability, and automation functions.
Key features include: - Horizontally positioned redox cell – ensures an ample reaction time and reaction zone within the cell, which promotes the sample's redox reaction and achieves long-term stability
- Simplified maintenance – the unique horizontal design of the redox cell makes it quicker to access and replace the inner pyro-tube without disassembling the redox cell.
- First ultrashort flow path (patent pending) – as the flow path becomes shorter, the sensitivity for both peak area and signal-to-noise ratio increases by up to 2.5 times
- Automation functions – enables operators to finish preparations such as gas control, temperature control and conditioning with a single touch
... Read More |