GC System

A gas chromatograph separates volatile gaseous compounds carried by an inert gas such as helium, nitrogen, argon or hydrogen across a solid stationary phase. Components in a gas chromatograph include a sample injector, flow controller, GC column, column oven, a detector, and a computer for data acquisition and analysis. A combination of electronic sensors and pumps maintain either a constant or variable mobile phase flow rate from 0.001 to 100 mL per minute. GC instruments typically have a maximum temperature of 350C to 450C.

Gas Chromatographs can be equipped with several types of detectors including: a flame ionization detector (FID), a thermal conductivity detector (TCD), a flame photometric detector (FPD), an electron capture detector (ECD), and even a mass spectrometer, for example. Gas chromatography is a powerful standalone application used in many industries, especially environmental testing. However, GC instruments are also found in combination with mass spectrometers, refining the GC separation with additional mass analysis. Fast run times and robust data acquisition and analysis software are important features in a gas chromatograph.

Find, compare, and request a quote for GC systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanySRI InstrumentsSRI InstrumentsSRI InstrumentsSRI Instruments
ItemMultiple Gas Analyzer #5310C Portable Gas Chromatograph310C Portable GC8610C Gas Chromatograph
Catalog NumberMG58610C
PriceInquireInquireInquireInquire
Detector(s)TCD (Thermal Conductivity Detector), FID (Flame Ionization Detector) with MethanizerUp to 4 detectors simultaneously (TCD, FID, FPD, ECD, PID, HID, etc.)Up to 4 detectors simultaneously; choice of 16 detector types including FID, TCD, FPD, ECD, PID, and moreUp to 6 simultaneously, choice of 16 detector types
Temperature RangeAmbient to 400CAmbient to 400°C (programmable)Ambient to 400°CInquire
Injection PortsTwo 10-port gas sampling valvesSingle injector: On-column, Heated Flash Vaporization, Split/Splitless, or PTVOn-column, Heated Flash Vaporization, Split/Splitless, or PTV injectorInquire
DescriptionTop-selling SRI GC for multi-gas analysis. Separates H2, O2, N2, CH4, CO, CO2, C2H6, H2O, C3H8, C4H10, C5H12 and more.Smallest GC that retains full-sized laboratory instrument performance. Bench-top or field portable, extremely rugged and field transportable (UPS/FedEx shippable, airline check-in baggage). Column oven 5" W × 5" D × 3" H, accommodates capillary columns (4" dia coils) or 1/8" packed columns. All ... Read MoreCompact portable gas chromatograph supporting up to 4 detectors and multiple injector types. Features programmable temperature from ambient to 400°C with EPC-controlled carrier gas and USB-connected PeakSimple data system. Field portable and airline shippable.Inquire
Get QuoteInquireInquireInquireInquire

Articles