Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDilatometer Horizontal 831DIL 803 Dual Sample DilatometerDIL 820 HT HiTemp Vertical DilatometerMisura 3 ODHT Optical DilatometerOptical Fleximeter Misura® 3 FLEX
Catalog NumberDIL 831DIL 803 / DIL 803LDIL 821HT / DIL 822HTMisura 3 ODHTMisura® FLEX
Price
DescriptionPacked with automated features, the DIL 831 features  the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.

An instrument
... Read More
Two-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read MoreThe Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.

The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the

Temperature RangeInquire-160°C to 1650°C according to furnace typeRT – 2000°C / 300°C – 2300°CFrom RT up to 1650 °Cfrom RT up to 1600 °C (1750°C with HiTemp optional furnace)
Heating / Cooling RatesInquireInquireInquireInquireMax Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)
Sample HolderInquireInquireAl2O3, GraphiteInquireInquire
Sample Length0 to 25 mm0 to 50 mm0 to 25 mmInquireInquire
Sample Diameter12 mmMax. 7 or 10 mm10mm / 5mmInquireInquire
Get Quote