Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDilatometer Horizontal 831DIL 805 Series Quenching DilatometersDIL 806 Optical DilatometerHigh Resolution True Differential™ Horizontal Push Rod Dilatometer DIL 832HM 867 Heating Microscope
Citations
(6)
Catalog NumberDIL 831DIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 806DIL 832HM 867
Price
DescriptionPacked with automated features, the DIL 831 features  the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.

An instrument
... Read More
The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a... Read MoreResult of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the ... Read More
Temperature RangeInquire-150°C to 1300°C / 50°C to 1500°C-150°C to -600°CInquireRT – 1600 °C
Heating / Cooling RatesInquireInquireInquireInquireHeating Rate - 0,1 – 80 °C/min
Sample Length0 to 25 mmInquire0.3 – 30 mm0 to 25 mmInquire
Sample Diameter12 mmInquireInquire6mmInquire