Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 803 Dual Sample DilatometerDIL 820 Series Vertical DilatometerDilatometer Horizontal 831Heating Microscope Misura® 3 HSM/ HSMLHM 867 Heating Microscope
Catalog NumberDIL 803 / DIL 803LDIL 821 / DIL 822DIL 831Misura® 3 HSM / Misura® 3 HSMLHM 867
Price
DescriptionTwo-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.

Packed with automated features, the DIL 831 features  the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.

An instrument
... Read More
With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, ... Read MoreResult of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the ... Read More
Temperature Range-160°C to 1650°C according to furnace typeRT – 1100°C / RT – 1500°C / 100 – 1700°CInquireRT – 1650 °C / RT – 1600 °CRT – 1600 °C
Heating / Cooling RatesInquireInquireInquireMax Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/minHeating Rate - 0,1 – 80 °C/min
Sample HolderInquireFused silica, Al2O3InquireInquireInquire
Sample Length0 to 50 mm0 to 25 mm0 to 25 mmInquireInquire
Sample DiameterMax. 7 or 10 mm10mm / 5mm12 mmInquireInquire
Get Quote