| Description | Two-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducingTwo-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing the influence of measurement system expansion and increasing measurement accuracy under dynamic temperature conditions. The DIL 803 is designed for measurements under vacuum or inert gas while the DIL 803L is designed for measurements under air, making the DIL 803L ideally suited to measuring ceramic materials... Read More | This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast response of the DIL806 furnace, this makes the system particular well-suited for the analysis of dynamic processes that involve multiple temperature steps and dynamic heating rates.A high-performance LED emits a broad-width planar light beam onto the sample. The sample shadow is detected by a high-resolution CCD sensor. The signal is then evaluated by a digital edge-detection processor which provides a sensitive and precise measurement of dimensional change. This principle is known as the shadowed light method and provides an accurate and absolute measurement of the sample dimension with changing temperature.... Read More | With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, ranging from room temperature up to a maximum of 1650°C, without any contact with the sample.... Read More | Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the optimization of all the industrial processes that involve thermal cycles.... Read More | The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the centre of the sample while this sags or springs up during the heat treatment.... Read More |
| Heating / Cooling Rates | Inquire | Inquire | Max Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/min | Heating Rate - 0,1 – 80 °C/min | Max Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace) |