Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 802 Differential DilatomerDIL 801 Single Sample DilatomerDIL 803 Dual Sample DilatometerDIL 806 Optical DilatometerMisura 3 ODHT Optical Dilatometer
Citations
(8)
(6)
Catalog NumberDIL 802/802LDIL 801 / DIL 801LDIL 803 / DIL 803LDIL 806Misura 3 ODHT
Price
DescriptionFor highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the

The best value for money for single sample direct measurement for routine evaluation

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the

Two-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read More
Temperature Range-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace type-150°C to -600°CFrom RT up to 1650 °C
Sample Length0 to 50 mm0 to 50 mm0 to 50 mm0.3 – 30 mmInquire
Sample Diametermax. 7 or 10 mm after conversion to DIL 801: 14 or 20 mmmax. 14 or 20 mmMax. 7 or 10 mmInquireInquire
Get Quote