| Description | The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.Available in two different models (DIL 821 and DIL 822), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822, the result is simply the best possible sensitivity and CTE accuracy on the market.... Read More | Two-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducingTwo-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing the influence of measurement system expansion and increasing measurement accuracy under dynamic temperature conditions. The DIL 803 is designed for measurements under vacuum or inert gas while the DIL 803L is designed for measurements under air, making the DIL 803L ideally suited to measuring ceramic materials... Read More | The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units used to measure dimensional changes under extreme conditions of controlled heating and cooling.... Read More | Packed with automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument Packed with automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument offering scientists the ideal tool for R&D laboratories to measure the linear thermal expansion and to calculate the Coefficient of Thermal Expansion (CTE) of ceramics, glasses, high performance materials, polymers, metals and alloys with great accuracy.
Features include: - Linear motor for a sample load range of 0.01 to 1.00 N, with a force resolution of 0.01 N and linearity better than 0.01 N across the total measuring range of 5000 µm, to guarantee the correct sample load regardless of the material tested.
- Patented optical incremental encoder to bring length measurement resolution down to a best in class 1 nm, and to allow the measurement of shorter samples yet preserving an outstanding ?L resolution. Its newly designed measuring head housing and the active electrical thermal stabilization ensure unprecedented stability of the detection core. This, combined with the unique design of TA Instruments furnaces, results in a zero temperature-gradient across the specimen and an industry leading CTE accuracy for single sample push rod dilatometers of 0.03 x 10-6 K-1.
- Automatic recording of the initial sample length.
- Water cooled furnaces providing a very dynamic temperature programming with a maximum heating rate of 50 K/min and industry unmatched cool down time of 13 minutes from 1000°C to room temperature. *This is up to 15 times shorter than competitive instruments.*
- Integrated electronics providing network connection, while the integrated touch screen allows you to perform many functions directly on the instrument and shows, in real time, measurement parameters and test’s time-to-completion.
... Read More | Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D laboratories for the optimization of all the industrial processes that involve thermal cycles.
The Heating Microscope mode uses a 5Mpix high resolution camera to study the physical behavior of the materials during the industrial firing cycles.
With the Morphometrics applicative it is possible, in real-time during the analysis, to automatically calculate and visualize different characteristic temperatures and parameters selectable by the user.
Capable to analyze samples in a wide range of shapes and sizes (for example a 3mm sample and simultaneously a 10mm sample), ODP 868 can simultaneously analyze up to 8 samples of ISO standard size.... Read More |