| Description | The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.Available in two different models (DIL 821 and DIL 822), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822, the result is simply the best possible sensitivity and CTE accuracy on the market.... Read More | Two-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducingTwo-samples simultaneous operation to maximize productivity without comprises on results.To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing the influence of measurement system expansion and increasing measurement accuracy under dynamic temperature conditions. The DIL 803 is designed for measurements under vacuum or inert gas while the DIL 803L is designed for measurements under air, making the DIL 803L ideally suited to measuring ceramic materials... Read More | The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units used to measure dimensional changes under extreme conditions of controlled heating and cooling.... Read More | DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, aDIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal push-rod dilatometer available on the market, regardless of the application or the material to be tested.
The sample load is ensured by a linear motor with a range of 0.01 to 1.00 N, a force resolution of 0.01 N and a linearity better than 0.01 N across the total measuring range of 5000 µm.
The patented optical incremental encoder brings length measurement’s true resolution down to a best in class 1 nm. This allows for the measurement of shorter samples yet preserving an outstanding ΔL resolution.
The newly designed measuring head housing and the active electrical thermal stabilization ensure unprecedented stability of the detection core. Combined with TA Instruments exclusive True Differential™ technology and the unique design of TA Instruments furnaces, results in the DIL 832 delivering an industry leading CTE accuracy of 0.01 x 10-6 K-1.
The DIL 832 automatically records the initial sample length and is capable of up to a maximum sample length of 25 mm and a maximum diameter of 6 mm .
The water cooled furnaces provide a very dynamic temperature programming capability with a maximum heating rate of 50 K/min, but most of all a cool down time as short as 13 minutes from 1000°C to room temperature, up to 15 times shorter than competitive instruments.
The integrated electronics provide network connection, and the integrated touch screen allows you to perform many functions directly on the instrument and shows, in real time, measurement parameters and test’s time-to-completion.... Read More | Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of dimensional changes up to 15% in expansion and down to 50% in shrinkage of the original dimensions. It enables to precisely study materials’ expansion, sintering or bloating and analyzes the sample behaviour throughout the entire industrial firing cycle up to a maximum temperature of 1650 °C with heating rates up to 80 °C/min.... Read More |