Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 805 Series Quenching DilatometersDIL 802 Differential DilatomerDIL 803 Dual Sample DilatometerDIL 820 HT HiTemp Vertical DilatometerMisura 3 ODHT Optical Dilatometer
Citations
(8)
Catalog NumberDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 802/802LDIL 803 / DIL 803LDIL 821HT / DIL 822HTMisura 3 ODHT
Price
DescriptionThe DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the

Two-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read More
Temperature Range-150°C to 1300°C / 50°C to 1500°C-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace typeRT – 2000°C / 300°C – 2300°CFrom RT up to 1650 °C
Sample HolderInquireInquireInquireAl2O3, GraphiteInquire
Sample LengthInquire0 to 50 mm0 to 50 mm0 to 25 mmInquire
Sample DiameterInquiremax. 7 or 10 mm after conversion to DIL 801: 14 or 20 mmMax. 7 or 10 mm10mm / 5mmInquire