Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 805 Series Quenching DilatometersDIL 802 Differential DilatomerDIL 806 Optical DilatometerDilatometer Horizontal 831Optical Fleximeter Misura® 3 FLEX
Citations
(8)
(6)
Catalog NumberDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 802/802LDIL 806DIL 831Misura® FLEX
Price
DescriptionThe DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the

This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast Packed with automated features, the DIL 831 features  the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.

An instrument
... Read More
The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.

The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the

Temperature Range-150°C to 1300°C / 50°C to 1500°C-160°C to 1650°C according to furnace type-150°C to -600°CInquirefrom RT up to 1600 °C (1750°C with HiTemp optional furnace)
Heating / Cooling RatesInquireInquireInquireInquireMax Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)
Sample LengthInquire0 to 50 mm0.3 – 30 mm0 to 25 mmInquire
Sample DiameterInquiremax. 7 or 10 mm after conversion to DIL 801: 14 or 20 mmInquire12 mmInquire