Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 805 Series Quenching DilatometersDIL 801 Single Sample DilatomerDIL 802 Differential DilatomerHigh Resolution True Differential™ Horizontal Push Rod Dilatometer DIL 832Optical Fleximeter Misura® 3 FLEX
Citations
(8)
Catalog NumberDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 801 / DIL 801LDIL 802/802LDIL 832Misura® FLEX
Price
DescriptionThe DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

The best value for money for single sample direct measurement for routine evaluation

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the

For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the

DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a... Read MoreThe Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.

The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the

Temperature Range-150°C to 1300°C / 50°C to 1500°C-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace typeInquirefrom RT up to 1600 °C (1750°C with HiTemp optional furnace)
Heating / Cooling RatesInquireInquireInquireInquireMax Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)
Sample LengthInquire0 to 50 mm0 to 50 mm0 to 25 mmInquire
Sample DiameterInquiremax. 14 or 20 mmmax. 7 or 10 mm after conversion to DIL 801: 14 or 20 mm6mmInquire
Get Quote