Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemDIL 805 Series Quenching DilatometersDIL 806 Optical DilatometerDIL 820 HT HiTemp Vertical DilatometerDilatometer Horizontal 831Heating Microscope Misura® 3 HSM/ HSML
Citations
(6)
Catalog NumberDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 806DIL 821HT / DIL 822HTDIL 831Misura® 3 HSM / Misura® 3 HSML
Price
DescriptionThe DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic Packed with automated features, the DIL 831 features  the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.

An instrument
... Read More
With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, ... Read More
Temperature Range-150°C to 1300°C / 50°C to 1500°C-150°C to -600°CRT – 2000°C / 300°C – 2300°CInquireRT – 1650 °C / RT – 1600 °C
Heating / Cooling RatesInquireInquireInquireInquireMax Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/min
Sample HolderInquireInquireAl2O3, GraphiteInquireInquire
Sample LengthInquire0.3 – 30 mm0 to 25 mm0 to 25 mmInquire
Sample DiameterInquireInquire10mm / 5mm12 mmInquire