Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemMisura 3 ODHT Optical DilatometerDIL 803 Dual Sample DilatometerDIL 805 Series Quenching DilatometersODP 868 Optical Dilatometer with Heating Microscope and Fleximeter ModesOptical Fleximeter Misura® 3 FLEX
Citations
(1)
Catalog NumberMisura 3 ODHTDIL 803 / DIL 803LDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TODP 868Misura® FLEX
Price
DescriptionBased upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read MoreTwo-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D ... Read MoreThe Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.

The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the

Temperature RangeFrom RT up to 1650 °C-160°C to 1650°C according to furnace type-150°C to 1300°C / 50°C to 1500°CFrom RT up to 1650 °Cfrom RT up to 1600 °C (1750°C with HiTemp optional furnace)
Heating / Cooling RatesInquireInquireInquireHeating Rate – 0,1 – 100 °C/min (200 °C/sec in Flash mode)Max Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)
Sample LengthInquire0 to 50 mmInquireUp to 85mmInquire
Sample DiameterInquireMax. 7 or 10 mmInquireInquireInquire
Get Quote