Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemMisura 3 ODHT Optical DilatometerDIL 801 Single Sample DilatomerDIL 802 Differential DilatomerDIL 806 Optical DilatometerHM 867 Heating Microscope
Citations
(8)
(6)
Catalog NumberMisura 3 ODHTDIL 801 / DIL 801LDIL 802/802LDIL 806HM 867
Price
DescriptionBased upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read MoreThe best value for money for single sample direct measurement for routine evaluation

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the

For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the

This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the ... Read More
Temperature RangeFrom RT up to 1650 °C-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace type-150°C to -600°CRT – 1600 °C
Heating / Cooling RatesInquireInquireInquireInquireHeating Rate - 0,1 – 80 °C/min
Sample LengthInquire0 to 50 mm0 to 50 mm0.3 – 30 mmInquire
Sample DiameterInquiremax. 14 or 20 mmmax. 7 or 10 mm after conversion to DIL 801: 14 or 20 mmInquireInquire
Get Quote