Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemMisura 3 ODHT Optical DilatometerDIL 801 Single Sample DilatomerDIL 805 Series Quenching DilatometersDIL 820 HT HiTemp Vertical DilatometerHeating Microscope Misura® 3 HSM/ HSML
Citations
Catalog NumberMisura 3 ODHTDIL 801 / DIL 801LDIL 805L / DIL 805A / DIL 805A/D / DIL 805A/D/TDIL 821HT / DIL 822HTMisura® 3 HSM / Misura® 3 HSML
Price
DescriptionBased upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read MoreThe best value for money for single sample direct measurement for routine evaluation

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the

The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units

The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, ... Read More
Temperature RangeFrom RT up to 1650 °C-160°C to 1650°C according to furnace type-150°C to 1300°C / 50°C to 1500°CRT – 2000°C / 300°C – 2300°CRT – 1650 °C / RT – 1600 °C
Heating / Cooling RatesInquireInquireInquireInquireMax Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/min
Sample HolderInquireInquireInquireAl2O3, GraphiteInquire
Sample LengthInquire0 to 50 mmInquire0 to 25 mmInquire
Sample DiameterInquiremax. 14 or 20 mmInquire10mm / 5mmInquire
Get Quote