| Description | Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D laboratories for the optimization of all the industrial processes that involve thermal cycles.
The Heating Microscope mode uses a 5Mpix high resolution camera to study the physical behavior of the materials during the industrial firing cycles.
With the Morphometrics applicative it is possible, in real-time during the analysis, to automatically calculate and visualize different characteristic temperatures and parameters selectable by the user.
Capable to analyze samples in a wide range of shapes and sizes (for example a 3mm sample and simultaneously a 10mm sample), ODP 868 can simultaneously analyze up to 8 samples of ISO standard size.... Read More | For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the True Differential design negates the influence of measurement system expansion on the sample measurement. This measurement design is of particular benefit for dynamic temperature programs such as those employed in Rate-Controlled-Sintering (RCS) and for measurements at lower temperatures. The DIL 802 is designed for measurements under vacuum or inert gas while the DIL 802L is designed for measurements under air.... Read More | This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast This optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast response of the DIL806 furnace, this makes the system particular well-suited for the analysis of dynamic processes that involve multiple temperature steps and dynamic heating rates.A high-performance LED emits a broad-width planar light beam onto the sample. The sample shadow is detected by a high-resolution CCD sensor. The signal is then evaluated by a digital edge-detection processor which provides a sensitive and precise measurement of dimensional change. This principle is known as the shadowed light method and provides an accurate and absolute measurement of the sample dimension with changing temperature.... Read More | The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic The 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic dilatometers with horizontal design.Available in two different models (DIL 821HT and DIL 822HT), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822HT, the result is simply the best possible sensitivity and CTE accuracy in the high temperatures segment.... Read More | The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the centre of the sample while this sags or springs up during the heat treatment.... Read More |