| Description | With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, With a proven record of hundreds of units installed globally in the laboratories of the most prominent Companies and Universities in the ceramics, metals and energy markets, Heating Microscopes Misura® 3 HSM and Misura® 3 HSML study the behaviour of a material subjected to a thermal treatment, ranging from room temperature up to a maximum of 1650°C, without any contact with the sample.... Read More | The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.All four instruments are fully automated, self-contained units used to measure dimensional changes under extreme conditions of controlled heating and cooling.... Read More | Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of dimensional changes up to 15% in expansion and down to 50% in shrinkage of the original dimensions. It enables to precisely study materials’ expansion, sintering or bloating and analyzes the sample behaviour throughout the entire industrial firing cycle up to a maximum temperature of 1650 °C with heating rates up to 80 °C/min.... Read More | Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D laboratories for the optimization of all the industrial processes that involve thermal cycles.
The Heating Microscope mode uses a 5Mpix high resolution camera to study the physical behavior of the materials during the industrial firing cycles.
With the Morphometrics applicative it is possible, in real-time during the analysis, to automatically calculate and visualize different characteristic temperatures and parameters selectable by the user.
Capable to analyze samples in a wide range of shapes and sizes (for example a 3mm sample and simultaneously a 10mm sample), ODP 868 can simultaneously analyze up to 8 samples of ISO standard size.... Read More | The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the The Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the centre of the sample while this sags or springs up during the heat treatment.... Read More |
| Heating / Cooling Rates | Max Heating Rate - 0,1- 80 °C/min / 0,1- 30 °C/min | Inquire | Inquire | Heating Rate – 0,1 – 100 °C/min (200 °C/sec in Flash mode) | Max Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace) |