Dilatometer / Dilatometry (DIL)

Dilatometry (DIL) measures volume changes caused by physical and chemical processes. They are used in manufacturing, engineering, materials science, and chemistry labs. When working with a dilatometer, the first step is to load the sample into the machine. The sample is subjected to physical or chemical processes, most often in the form of heating from a furnace, and a sensor picks up on the volume changes.

Dilatometers can be used to calculate a material's coefficient of thermal expansion, softening point, glass transition temperature, Curie point, crystalline transformation, phase transition, and amount of shrinkage. When purchasing dilatometry equipment, it is important to consider the type of material that will be tested, the method of capture for measurements, and the software used.

CompanyTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters CorporationTA Instruments – a division of Waters Corporation
ItemOptical Fleximeter Misura® 3 FLEXDIL 801 Single Sample DilatomerDIL 803 Dual Sample DilatometerHigh Resolution True Differential™ Horizontal Push Rod Dilatometer DIL 832Misura 3 ODHT Optical Dilatometer
Catalog NumberMisura® FLEXDIL 801 / DIL 801LDIL 803 / DIL 803LDIL 832Misura 3 ODHT
Price
DescriptionThe Optical Fleximeter Misura® FLEX is the ideal instrument to study flexural behaviour of materials undergoing real industrial firing cycles without application of loads.

The optical fleximeter analyzes a sample that is suspended between two holding rods 60mm spaced. A HiRes videocamera frames the

The best value for money for single sample direct measurement for routine evaluation

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the

Two-samples simultaneous operation to maximize productivity without comprises on results.

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing

DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a... Read MoreBased upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of ... Read More
Temperature Rangefrom RT up to 1600 °C (1750°C with HiTemp optional furnace)-160°C to 1650°C according to furnace type-160°C to 1650°C according to furnace typeInquireFrom RT up to 1650 °C
Heating / Cooling RatesMax Heating Rate – 0,01- 30 °C/min (20°C/min with HiTemp optional furnace)InquireInquireInquireInquire
Sample LengthInquire0 to 50 mm0 to 50 mm0 to 25 mmInquire
Sample DiameterInquiremax. 14 or 20 mmMax. 7 or 10 mm6mmInquire