Description | DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, aDIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal push-rod dilatometer available on the market, regardless of the application or the material to be tested.
The sample load is ensured by a linear motor with a range of 0.01 to 1.00 N, a force resolution of 0.01 N and a linearity better than 0.01 N across the total measuring range of 5000 µm.
The patented optical incremental encoder brings length measurement’s true resolution down to a best in class 1 nm. This allows for the measurement of shorter samples yet preserving an outstanding ΔL resolution.
The newly designed measuring head housing and the active electrical thermal stabilization ensure unprecedented stability of the detection core. Combined with TA Instruments exclusive True Differential™ technology and the unique design of TA Instruments furnaces, results in the DIL 832 delivering an industry leading CTE accuracy of 0.01 x 10-6 K-1.
The DIL 832 automatically records the initial sample length and is capable of up to a maximum sample length of 25 mm and a maximum diameter of 6 mm .
The water cooled furnaces provide a very dynamic temperature programming capability with a maximum heating rate of 50 K/min, but most of all a cool down time as short as 13 minutes from 1000°C to room temperature, up to 15 times shorter than competitive instruments.
The integrated electronics provide network connection, and the integrated touch screen allows you to perform many functions directly on the instrument and shows, in real time, measurement parameters and test’s time-to-completion.... Read More | The best value for money for single sample direct measurement for routine evaluationSuitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the The best value for money for single sample direct measurement for routine evaluationSuitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the DIL 801L is designed for measurements in air, making the DIL 801L ideally suited to measuring ceramic materials which are often processed in air.... Read More | For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the True Differential design negates the influence of measurement system expansion on the sample measurement. This measurement design is of particular benefit for dynamic temperature programs such as those employed in Rate-Controlled-Sintering (RCS) and for measurements at lower temperatures. The DIL 802 is designed for measurements under vacuum or inert gas while the DIL 802L is designed for measurements under air.... Read More | The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.The 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.Available in two different models (DIL 821 and DIL 822), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822, the result is simply the best possible sensitivity and CTE accuracy on the market.... Read More | Packed with automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument Packed with automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument offering scientists the ideal tool for R&D laboratories to measure the linear thermal expansion and to calculate the Coefficient of Thermal Expansion (CTE) of ceramics, glasses, high performance materials, polymers, metals and alloys with great accuracy.
Features include:
- Linear motor for a sample load range of 0.01 to 1.00 N, with a force resolution of 0.01 N and linearity better than 0.01 N across the total measuring range of 5000 µm, to guarantee the correct sample load regardless of the material tested.
- Patented optical incremental encoder to bring length measurement resolution down to a best in class 1 nm, and to allow the measurement of shorter samples yet preserving an outstanding ?L resolution. Its newly designed measuring head housing and the active electrical thermal stabilization ensure unprecedented stability of the detection core. This, combined with the unique design of TA Instruments furnaces, results in a zero temperature-gradient across the specimen and an industry leading CTE accuracy for single sample push rod dilatometers of 0.03 x 10-6 K-1.
- Automatic recording of the initial sample length.
- Water cooled furnaces providing a very dynamic temperature programming with a maximum heating rate of 50 K/min and industry unmatched cool down time of 13 minutes from 1000°C to room temperature. *This is up to 15 times shorter than competitive instruments.*
- Integrated electronics providing network connection, while the integrated touch screen allows you to perform many functions directly on the instrument and shows, in real time, measurement parameters and test’s time-to-completion.
... Read More |