Description | The best value for money for single sample direct measurement for routine evaluationSuitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the The best value for money for single sample direct measurement for routine evaluationSuitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the DIL 801L is designed for measurements in air, making the DIL 801L ideally suited to measuring ceramic materials which are often processed in air.... Read More | For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer.For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the True Differential design negates the influence of measurement system expansion on the sample measurement. This measurement design is of particular benefit for dynamic temperature programs such as those employed in Rate-Controlled-Sintering (RCS) and for measurements at lower temperatures. The DIL 802 is designed for measurements under vacuum or inert gas while the DIL 802L is designed for measurements under air.... Read More | DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, aDIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D laboratory for the characterization of mechanical and dimensional properties: TA Instruments exclusive True Differential™ technology, the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal push-rod dilatometer available on the market, regardless of the application or the material to be tested.
The sample load is ensured by a linear motor with a range of 0.01 to 1.00 N, a force resolution of 0.01 N and a linearity better than 0.01 N across the total measuring range of 5000 µm.
The patented optical incremental encoder brings length measurement’s true resolution down to a best in class 1 nm. This allows for the measurement of shorter samples yet preserving an outstanding ΔL resolution.
The newly designed measuring head housing and the active electrical thermal stabilization ensure unprecedented stability of the detection core. Combined with TA Instruments exclusive True Differential™ technology and the unique design of TA Instruments furnaces, results in the DIL 832 delivering an industry leading CTE accuracy of 0.01 x 10-6 K-1.
The DIL 832 automatically records the initial sample length and is capable of up to a maximum sample length of 25 mm and a maximum diameter of 6 mm .
The water cooled furnaces provide a very dynamic temperature programming capability with a maximum heating rate of 50 K/min, but most of all a cool down time as short as 13 minutes from 1000°C to room temperature, up to 15 times shorter than competitive instruments.
The integrated electronics provide network connection, and the integrated touch screen allows you to perform many functions directly on the instrument and shows, in real time, measurement parameters and test’s time-to-completion.... Read More | Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of Based upon the double beam design, with one optical path always aligned to the top of the specimen while the second focused on sample lower end correcting for any thermal-profile related drift, the contact-less Vertical Optical Dilatometer Misura® 3 ODHT allows to carry out measurements of dimensional changes up to 15% in expansion and down to 50% in shrinkage of the original dimensions. It enables to precisely study materials’ expansion, sintering or bloating and analyzes the sample behaviour throughout the entire industrial firing cycle up to a maximum temperature of 1650 °C with heating rates up to 80 °C/min.... Read More | Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, ODP 868 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of ODP 868 the most innovative tool for production and R&D laboratories for the optimization of all the industrial processes that involve thermal cycles.
The Heating Microscope mode uses a 5Mpix high resolution camera to study the physical behavior of the materials during the industrial firing cycles.
With the Morphometrics applicative it is possible, in real-time during the analysis, to automatically calculate and visualize different characteristic temperatures and parameters selectable by the user.
Capable to analyze samples in a wide range of shapes and sizes (for example a 3mm sample and simultaneously a 10mm sample), ODP 868 can simultaneously analyze up to 8 samples of ISO standard size.... Read More |