Description | The special sulfur analyzer Based on the worldwide longest tradition in the analysis of the elements CHNS and O Elementar has developed an analyzer for carbon and sulfur which combines highest analytical performance with automatic sample throughput.
The sample handling by pelleting or use of tin The special sulfur analyzer Based on the worldwide longest tradition in the analysis of the elements CHNS and O Elementar has developed an analyzer for carbon and sulfur which combines highest analytical performance with automatic sample throughput.
The sample handling by pelleting or use of tin capsules and fully automatic injection into a high temperature combustion zone is typical for our elemental analyzers. The fast and sensitive SO2/CO2 determination by means of IR detection is specific to the requirements of analysis for sulfur and carbon, e.g. in coal, soil or waste. It is characterized by special sensitivity and easy handling... Read More | TOC analysis of environmental water and wastewater at its best
TOC Analyzers from Elementar based on catalytic high-temperature combustion have been providing support to environmental and wastewater laboratories for decades. Now Elementar’s new TOC/TNb analyzer, enviro TOC, combines the technicalTOC analysis of environmental water and wastewater at its best
TOC Analyzers from Elementar based on catalytic high-temperature combustion have been providing support to environmental and wastewater laboratories for decades. Now Elementar’s new TOC/TNb analyzer, enviro TOC, combines the technical know-how of its predecessor, the vario TOC select, with innovative technologies:
the powerful furnace, variable mode changes, real matrix separation with SALTTRAP and the stable, wide-range IR are complemented by a completely new autosampler system and a novel chemiluminescence detection system. This makes enviro TOC the ideal, future-oriented instrument for flexible and efficient TOC and TNb determination in environmental and wastewater samples.
- Designed for environmental samples
The analysis of TOC in wastewater to assess organic contamination or to evaluate the cleaning efficiency of sewage treatment plants is an international standard procedure. Also, TOC and TNb determination are indispensable for monitoring organic pollution and nitrogen load in surface waters.
The enviro TOC is tailored to the analysis of TOC, NPOC, TC, TIC, DOC, POC or TNb in these matrices. Samples are injected with a 60-position autosampler. Integrated rinsing functions minimize carryover during the analysis of particle-containing samples. In addition, the measurement of soil samples or waste is also possible without time-consuming instrument modifications. As one of the few analyzers on the market, enviro TOC offers fully automatic TOC determination in solid and liquid samples with one system.
- TOC analyzer with flexible nitrogen determination
The enviro TOC enables simultaneous TNb determination either using the proven EC cell technology or a novel, integrated chemiluminescence detector (CLD). The innovative CLD concept provides stable conditions for NO measurement in the carrier gas. Consequently, the NO signal is linearly correlated with the TNb concentration over a large measurement range. The built-in CLD does not require additional laboratory space and delivers extremely stable values, which simplifies calibration as well as result evaluation.
- Real matrix separation with SALTTRAP
During the combustion of salt-containing samples, salts crystallize in the combustion tube. If the crystallization occurs directly on the quartz glass or in the catalyst, their lifetime is significantly reduced. The unique SALTTRAP of the enviro TOC guarantees user-friendly maintenance intervals of the combustion tube and the catalyst even for concentrated salt solutions, thus saving running costs during operation. Depending on the nature of the salt, a slight decrease in crystallization can be achieved by reducing the combustion temperature. However, only SALTTRAP guarantees truly effective glass corrosion protection, because the salts are trapped directly at the point where they melt.
- Easy and cost-effective maintenance
The user-friendly maintenance concept of the enviro TOC ensures the most efficient routine analysis: Our goal is that the maximum lifetime of the instrument can be reached with minimum maintenance effort. Consequently, all consumables can be easily replaced by the user. Clearly arranged, easily accessible components guarantee that most maintenance work can be carried out independently within a very short time. This saves running costs and avoids downtime of the instrument.
- Analysis methods
High-temperature catalytic carbon oxidation up to 1200 °C and CO2 detection with NDIR for TOC, NPOC, TC, TIC, POC (VOC), DOC. TNb determination simultaneously with CLD or EC cell (option).
- Innovative detectors
Customized, integrated detectors for CO2 and NO determination. Variable sample volumes allow multipoint calibration from a single standard solution and avoid dilution errors. Extraordinary linearity over a large calibration range.
- Modular concept for liquids and solids analysis
Automatic sample feeders for liquids and solids, alternatively cost-efficient solutions with manual sample change. Quick and easy exchangeable. Can be upgraded at any time.
- SALTTRAP
The innovative combustion tube concept enables real matrix separation and offers maximum protection of the combustion tube. Designed for analyses of salt-containing samples, particles or other complicated sample matrices.
- Software with high performance and maximum flexibility
Instrument control with a Windows standard PC, control and evaluation software with flexible calibration features, advanced math operations, and intuitive troubleshooting. Integrated maintenance software and comprehensive help menu.
- Robust furnace
Working temperatures up to 1200 °C. Suitable and flexible temperature settings for salt-containing solutions (~720-750 °C), particle-containing solutions (850 °C), and solids (> 900 °C) with one furnace.
- Easy, compact, economical
The unique instrument concept is characterized by easy handling and optimized for low maintenance costs – with high flexibility and analytical performance. ... Read More | Matrix-independent determination of N and C at trace levels
The UNICUBE trace measures low-level nitrogen and carbon concentrations in solids and highly viscous liquids with a detection limit of 10 mg/kg. Its speciality: nitrogen and carbon determination are carried out using the Dumas method, Matrix-independent determination of N and C at trace levels
The UNICUBE trace measures low-level nitrogen and carbon concentrations in solids and highly viscous liquids with a detection limit of 10 mg/kg. Its speciality: nitrogen and carbon determination are carried out using the Dumas method, which involves the removal of interfering gases during reduction and subsequent detection of the target gases using a thermal conductivity detector. As such, the UNICUBE trace is able to combine the benefits of the matrix-independent Dumas method with high sensitivity.
With UNICUBE trace, sample digestion is carried out via catalytic combustion at a temperature of 950°C, with the nitrogen and carbon-containing components in the sample forming a mixture of different oxides and N2. The resulting gases then pass through the reduction tube, where carbon compounds are safely reduced to CO2 and nitrogen compounds to N2. After removing other combustion products like H2O and SO2, CO2 and N2 are measured by thermal conductivity detection.
The system is designed for easy, low-maintenance operation; matrix-independent analysis allows the use of a standard ‘universal’ calibration for any sample type. The front door of the analyser opens to give excellent access for the replacement of consumables - exchanging the combustion and reduction tube is simple, thanks to the slide-out furnace.
What’s more, Elementar provides a 10-year warranty on both the furnace and thermal conductivity cell, thus ensuring that UNICUBE trace can continue delivering a stable and reliable performance for laboratories.... Read More | The art of elemental analysis Whether in coal, oil or soil analysis, the elemental analysis of macro samples is a particularly technical challenge for an analyzer. Elementar has solved this task in a sophisticated way by offering the vario MACRO cube. New technical solutions combined with well The art of elemental analysis Whether in coal, oil or soil analysis, the elemental analysis of macro samples is a particularly technical challenge for an analyzer. Elementar has solved this task in a sophisticated way by offering the vario MACRO cube. New technical solutions combined with well proven techniques allow the simultaneous determination of CHNS of samples up to the gram range. The worldwide only analyzer which makes this possible in one fully automatic step.
The elaborate design of the "cube" instruments is good looking and makes this perfect function possible. Ergonomics and functionality are finely linked here. vario MACRO cube can be adjusted to today's and tomorrow's requirements due to its modularity. However, the most important requirement of an analyzer is still the accuracy of the analysis. And vario MACRO cube simply works accurate.... Read More |
Measurement Mode(s) | CS | TOC, NPOC, TC, TIC, POC, DOC, TNb*
*optionally available | Nitrogen determination at trace levels | CHNS, CNS, CHN, CN, N, S, O, Cl, TIC |