Welcome Guest
Sign In
Register
Products
New Products
Featured Products
Featured Brands
Popular Categories
Spectrophotometer
Liquid Handling Robotics
IR / FTIR Spectrometers
DNA Thermal Cycler
Lab Water Systems
XRF Spectrometers
Ultra Low Temp Freezers
Particle Size Analyzer
HPLC Instruments
Cell Culture Incubator
By Application
Cannabis Testing & Analysis
Clinical Diagnostics & Testing
Environmental Testing
Food Testing
Forensics
Life Science Research
Lithium Battery Testing
Materials Testing
PFAS Testing
Pharmaceutical Lab
Chromatography
Mass Spectrometry
Cell and Gene Therapy
By Category
Analytical Instruments
General Lab Equipment
Lab Supplies
Lab Software
All Products
Applications
Battery Testing
PFAS Testing
Separation Science
Cell and Gene Therapy
Environmental Testing
Food Testing
Life Sciences
Materials Testing
Resources
Featured Articles
Guides & How-To's
Infographics
Whitepapers & App Notes
eBooks
LABTips
News
Research News
Product News
All News
Events
Multimedia
Videos
Webinars
Documentaries
Product Reviews
Write a Review
All Reviews
Register
Sign In
Labcompare
Products
Laboratory Analytical Instruments
Gas Chromatography Equipment
Gas Chromatograph Mass Spectrometer / GC MS Instrument
Ion Chromatography Instrument
Ion chromatography (IC) systems separate charged particles from a liquid and measure their concentration. IC systems can analyze particles such as anions, cations, organic salts, and proteins. They are used in environmental, manufacturing, food, pharmaceutical, and chemical industries. Key things to consider when purchasing an IC system include: number of samples, range of sample volume, whether eluent is generated by the system, flow and pressure of the column, and ease and functionality of the chromatography data system software.
Company
Sykam GmbH
Sykam GmbH
Sykam GmbH
Sykam GmbH
Sykam GmbH
Item
Sykam S 151-A Automatic Anion IC System
Sykam S 152-A Automatic Cation IC System
Sykam S 153-A Dual Anion/Cation IC System
Sykam S 155-A Compact Anion Ion Chromatograph
Sykam S 155-C Compact Cation Ion Chromatograph
Price
Inquire
Inquire
Inquire
Inquire
Inquire
Flow Rate
0.001–10 mL/min
0.001–10 mL/min
0.001–10 mL/min per channel
up to 10 mL/min
up to 10 mL/min
Detector(s)
Conductivity (20 nS/cm – 20,000 µS/cm)
Conductivity (20 nS/cm – 20,000 µS/cm)
2× Conductivity (20 nS/cm – 20,000 µS/cm)
Conductivity (20 nS/cm – 20,000 µS/cm)
Conductivity (20 nS/cm – 20,000 µS/cm)
Max. Pressure
40 MPa (5,800 psi)
40 MPa (5,800 psi)
40 MPa (5,800 psi) per pump
Inquire
Inquire
Get Quote
Inquire
Inquire
Inquire
Inquire
Inquire
Articles
Accurate Testing and Easy to Access Reports
It makes my work easy and accurate.
Online Monitoring Is Superb
Simple Ion Chromatography
IC with Multiple Applications
Faster Professional IC with Great Pressure Capabilities
Dionex and US EPA Collaborate to Improve Analysis of Highly Toxic Cr(VI) in Drinking Water
New Kanamycin and Amikacin Method Exceeds US Pharmacopeia Analysis Requirements
Common Cations and Amines Identification and Quantification Improved Using IC-MS
Enhanced Method for Monitoring Hydroxymethylfurfural Levels in Food and Biomass
Dionex Announces the 2011 Chromeleon International User Symposium Now Combined with the Dionex IC and LC International User Symposium
HPLC Application Note: Ultralow Detection Limits for Inorganic Anions and Cations in Power Station Boiler Water Analysis
Genevac and Dionex sign worldwide distribution agreement
Dionex Introduces New Anion Column for Gradient Separation of Multivalent Anions in Complex Sample Matrices
New Cation Column for Separation of Amines and Inorganic Cations in Complex Sample Matrices
Ion Gun Duo for SIMS/SNMS Applications
Thermo Fisher Scientific Wins the R&D 100 Award for its Groundbreaking Capillary Ion Chromatography System
Faster and Enhanced Determination of Nitrate and Nitrite in Milk
Cost-effective Determination of Inorganic Anions and Cations in Municipal Drinking Water
ISO Releases New Standard for the Determination of Bromate
Simplified and Reproducible Separation of Ethyl Sulfate Impurity in Indinavir Sulfate
Thermo Fisher Scientific Collaborates with US EPA to Improve Holding Time and MDLs for Chromate in Drinking Water
Direct HPAE-PAD Analysis of Sialic Acids in Glycoprotein Hydrolyzates
Pittcon Announces 2012 Award Recipients
Simplified and Direct Determination of Sialic Acids in Glycoproteins
Chromatographically Purified Bovine Albumins from Alfa Aesar
Thermo Fisher Scientific Launches European Seminar Series: “New Frontiers in Water Analysis”
Thermo Fisher Scientific Unveils New Sample Conductivity and pH Measurement Accessory for Ion Chromatography Systems
Practical Guidelines for Capillary Anion-Exchange Chromatography
Analysis of Organic Acids in Wastewater
Analysis of Nitrate and Nitrite in Milk
External Announcement: Rapid and Sensitive Determination of Biofuel Sugars by IC
External Announcement: Bisphosphonate Pharmaceuticals and Excipients by Capillary IC-MS
Capillary Ion Chromatography Column for Analysis of Organic Acids and Inorganic Anions
Determine Polyphosphates and Citrate in Shrimp in Just 15 Minutes
External Announcement: Dimethylamine Determination in Metformin HCI Drug Products
External Announcement: Seminars on Advanced Solutions for Nutraceutical Analysis
Thermo Fisher Scientific and METTLER TOLEDO Introduce Integrated Titration/Ion Chromatography System Designed to Streamline Water Analysis Workflow
Thermo Fisher Scientific and METTLER TOLEDO Introduce Integrated Titration/Ion Chromatography System Designed to Streamline Water Analysis Workflow
Thermo Fisher Scientific Features High Resolution Accurate Mass LC-MS Workflow at AAPS 2012
Ion Chromatography Method for Determination of Voriconazole Related-Compound F
Charge Detector for Ion Chromatography, Co-Developed by UT Arlington and Thermo Fisher Scientific, Receives Patent
Ion Chromatography System Purchasing Guide
Ion chromatography News from Thermo Fisher Scientific Thermo Fisher Scientific Introduces Next Generation High-Pressure Ion Chromatography System
External Announcement: Robust and Sensitive Method Measures Iodide in Infant Formula
METTLER TOLEDO and Thermo Fisher Scientific Introduce Combined Titration and Ion Chromatography
External Announcement: Fast Separations of Inorganic Ions in Water Samples with 4 µm Columns
High Pressure Ion Chromatography Speeds Determinations of Salton Sea Samples
External Announcement: High Pressure Ion Chromatography Speeds Determination of Cations in Wastewater
Ion Chromatography News from Thermo Fisher Scientific Thermo Fisher Scientific Introduces Next Generation Ion Chromatography Suppressor
Thermo Scientific Ion Chromatography and Expanded Range of LC Equipment Now Compatible with Waters’ Empower Software
Configuring a High Pressure Integrated Capillary Ion Chromatography System
Capillary Ion Chromatography Speeds Separation of Anions and Cations in Carbonated Beverages
Easy Determination of Total/Potential Sulfate and Total Chloride in Gasoline-Denatured Ethanol
Robust 15-Minute Analysis to Help Lithium-Ion Battery Development
Protein Glycosylation Evaluation in Less Than 10 µg of Protein Samples
Ion Chromatography Method Quantifies Ammonia in Tobacco Smoke
Ion Chromatography Easily Determines Methylamine in Drug Products
Ion Chromatography Determines Polyacrylic Acid in Pressurized Water Reactor Secondary Feed Water
Drinking Water Testing by Ion Chromatography using Ultrapure Water
50 Years of Ion Chromatography: What has, and hasn’t, Changed
IC’s Golden Jubilee: Deeper and More Sensitive Analysis
Easily Determine Trace Morpholine and More in Linezolid
How SLIM Changes Everything
Q&A: Award-winning PFAS Research Opens New Treatment Pathways
Keeping Drinking Water Safe: Precise, Reliable Determination of ‘Forever Chemicals’ Using Advanced Technology
Perspectives from ASMS 69: Part I