| Description | FluidX 0.48ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.48ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent 2D code laser etched in high contrast on the tube base, a permanent 1D linear barcode and human-readable number laser etched in high-contrast on the tube side. All three codes are identical and auditing processes guarantee all three codes match; standard 2D coding option is black on white. ... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12; working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block). Our FrameStar Roche Style plates are designed to achieve optimized assay 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12; working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block). Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100μl. The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The semi-skirted frame allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with the Roche LightCycler® 96 and 480 (with 96 well block)
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Standard plate comes with clear polypropylene wells on a clear polycarbonate frame
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request;
- Combi packs available with qPCR Seal (4ti-0560) and (for 4ti-0951) with Optically Clear Windowed qPCR Seal (4ti-0564)
... Read More | 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and polystyrene plates. This seal demonstrates good solvent resistance and can be used for low temperature and room temperature compound storage in DMSO and organic solvents. Pierce Heat Seal can be pierced with a pipette tip manually, or by a liquid handling robot. This seal can be resealed by applying another Pierce Seal straight on top of a previously pierced seal. A blue stripe on the sheet foils clearly indicates the non-sealing surface, for ease of seal orientation and handling. Pierce Heat Seal sheets are also available with a printed grid reference on the non-sealing surface. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Key Features: - Pierceable
- Resealable
- Seal integrity range: -20°C to 120°C
- Good solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Seals polypropylene and polystyrene plates
- Suitable for long term storage
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Available with printed grid reference (in sheet format, 4ti-0531/GR)
- Non-sterile as standard; sterilization available upon request
- Custom printing available on request
... Read More | CoolBox Ice-Free Cooling Workstation systems are bench top cooling workstations that provide sample cooling or freezing without ice, electricity or batteries. Ice-Free Cooling Workstation systems are versatile and accommodate a variety of sample formats and temperatures. The modular design enables CoolBox Ice-Free Cooling Workstation systems are bench top cooling workstations that provide sample cooling or freezing without ice, electricity or batteries. Ice-Free Cooling Workstation systems are versatile and accommodate a variety of sample formats and temperatures. The modular design enables the use of Thermoconductive Rack thermo-conductive sample modules to hold microfuge tubes, cryogenic vials, PCR tubes or plates, and more. Available in single or double capacity. - Ice-free cooling/freezing systems with lid or as open platform
- Fits a choice of Thermoconductive Rack modules
- Small footprint ideal for use in the hood especially in keeping temperature sensitive solutions cold
- CoolBox with lid keeps samples cold for up to 16 hours
- CoolBox with lid keeps samples frozen for up to 8 hours
- Open platform keeps samples cold for up to 4 hours
- The built-in 1-8ºC temperature indicator provides visual assurance of operational temperature while working
... Read More | FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available
FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available empty or pre-filled with caps
Suitable for manual use or for use with Azenta Life Sciences Semi-Automated Screw Cap Decappers/Recappers, Single Channel and IntelliXcap™ Automated Screw Cap Decappers/Recappers. - Enable uncapped tubes to be used immediately and then capped using an automated capping and de-capping system
- When used manually, by transferring caps from the carrier to the tube using a single tube transfer device, the operation becomes faster and the risk of contamination is reduced as cap handling is eliminated
- Available in cases of 10 or 50, empty or pre-filled with low-retention screw caps that can reduce sample loss
... Read More |
| Applications | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | PCR, qPCR, NGS | PCR, Storage Applications | Ideal for use in any application where samples need to remain cold or frozen, suitable for use in hoods | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |